MAINTENANCE
MAINTENANCE
•
J
r
•
l
Note!
• The fluff accumulated on the filter will block the air circulation,which will cause the
extension of drying time and energy consumption.
• Do disconnect the power cord before cleaning!
• Do not operate the dryer without the filter!
• Clean the filter after each use to prevent lint accumulation inside the dryer.
Clean heat exchanger
• As necessary,approx. once every 2 months,
remove the fluff from the heat exchanger
using the sponge or soft brush.
• When doing this,please use gloves.
Note!
The fluff can be removed more easily if it is
L.:
rst dampened.
Wash air condenser
Leave the dryer to cool down.
Residualwater may escape,place an absorbent
cloth under the maintenance cover.
1.Unlock the maintenance cover.
2. Completely open maintenace cover.
3. Screw both locking levers towards each other.
4.Pool out the air condenser.
5. Clean the air condenser completely,drain thoroughly.
6. Clean the seals.
7.Re-insert the air condenser, handle at the button!
8.Unscrew both locking levers.
9. Cloth the maintenance cover until it locks into position.
Please clean the air condenser approx,once every 3
months if frequently used.
Do not damage the air condenser!
Warning!
•
Trouble Shooting
Dispiay
Reason
Solutions
"FuW LED on
permanently
Container is full
Empty container
Water pump failure or water
level sensor failure
Please contact your
localservice center
if the problem
persists
Child Lock+ 9h
Temperature sensor error
Child Lock+ 6h
Humidity sensor error
Child Lock+ 3h
Heating problem
Warning!
• Only authorised technicans can carry out repairs.
• Before you call service,please check if you have dealt with the
fault yourself or if you have followed the user instructions.
• A technician will charge you for advice,even during the warranty period.
Clean with water only;do not use hard/sharp-edged objects!
Do not operate the dryer without the air condenser!
• During drying,water may collect between the window and the
seal,but this does not affect the function of your dryer
I
17