Scandium SC900WRS Installation Operation & Maintenance Download Page 6

Page 6

mild detergent. Do not scrub. 

NOTE:

 some discolouration of the frame may occur when washing in the 

dishwasher. 

CAUTION: 

Never use abrasive or oil based liquid cleaners.

•  If the grease filters are very dirty, the motor will extract only a small quantity of air, which reduces its 

efficiency. The grease deposits that build up on the filter are highly flammable and COULD EASILY CATCH 
FIRE. The manufacturer is not responsible in the event of fire due to poor maintenance of the grease filters.

• 

IMPORTANT:

 Never attempt to repair this appliance by yourself. Always refer to a qualified Service 

Technician. Remember to always switch off the electricity and unplug the connection before conducting 
maintenance or cleaning.

Light Bulb Replacement

•  Switch off the power to the rangehood and allow the bulb to cool.

•  Remove the bulb by turning it by hand in an anti clockwise direction.

•  Take care to avoid the bulb falling onto the hob top.

•  Replace the bulb by inserting it into the socket and hand turning in a clockwise direction.

Electrical Cord

Ensure the electric cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it 
must be replaced by the manufacturer, service agent or a similarly qualified person in order to avoid a hazard.

For Users

•  This product is designed for domestic use only and should not be used outside or for commercial 

applications. 

•  After use, always ensure that all controls are in the “OFF” position. When frying with a gas flame, take 

particular care not to allow the oil or grease in the pan to catch fire. (Flambé)

•  Do not leave the frying pan or fryer unattended, as the oil could overheat and catch fire.

•  Never flambé any foods beneath the rangehood. The flames could cause a fire.

•  Before carrying out any operation inside the rangehood, unplug the appliance from the electrical mains.

•  Adhere to the cleaning frequencies and intervals for changing the filters, as otherwise the accumulated 

grease could cause a fire or damage the product.

•  Any alterations made to the rangehood will void the warranty.

3. Maintenance and Service

499

280223

462

14

6

50

27

283

20

41

Max

425

Min3

05

600

78.5

17

4

B

A

D

C

Ø4

A,B,C,D =

520

500

19

10

10

2 10

462±2

305

283

223±

2

248

50

Ø1

30

±2

28

80

B

C

D

A

A

B

C

D

1

2

1

2

3

4

5

5

Summary of Contents for SC900WRS

Page 1: ...I N S T A L L A T I O N O P E R A T I O N M A I N T E N A N C E G U I D E RANGEHOOD SC900WRS SC900WTS...

Page 2: ...7 Rangehood Contents 7 Operation 7 Cutout Size 7 5 Installation 8 Mounting Instructions 8 For Installers 8 Mounting Points 9 Installation Example 10 Overview 11 Flexi Ducting 11 6 Condensation Informa...

Page 3: ...instruction manual in a safe place so you can refer to it at any time ATTENTION Installation regulation or maintenance of both gas and electric appliances should only be executed by qualified and auth...

Page 4: ...ing or maintenance The power outlet must be within reach of the power cord from the rangehood Check all contents of the packaging including all electrical functions of the rangehood before installatio...

Page 5: ...installations that fail to heed the applicable legislation on electrical safety with regard to both modes and materials The electrical technical data can be found inside the rangehood after removing t...

Page 6: ...place the bulb by inserting it into the socket and hand turning in a clockwise direction Electrical Cord Ensure the electric cord is not exposed to heat chemicals or sharp objects If the supply cord i...

Page 7: ...angehood Contents Male Plug Main Power 240V 10 amp connection Single Outlet 200mm Reducer For use with HiFlow VX120 motor Lamp Mounting Bracket 1 Extension Flue Piece 2 Main Flue For use with Isodrive...

Page 8: ...regulations concerning the expelling of air and install your rangehood in accordance with local laws and regulations IMPORTANT If the user decides to install the rangehood at a distance of less than m...

Page 9: ...tion Mounting Points The diagrams below are a guide for all mounting points For SC900WRS Model For SC900WTS Model Main Mounting Points 297 899 297 8 286 3 R3 5 R3 5 49 258 24 8 270 290 R3 5 24 8 R6 85...

Page 10: ...to secure the rangehood via the secondary mounting points Step 2 Feed through aluminium flexi duct from the outlet block to the kitchen ceiling Step 3 Place flue covers on Step 4 Attach wall mounting...

Page 11: ...he ducting Connect flexi ducting to the outlet on rangehood using duct tape or cable tie Please DO NOT rip the ducting 2 3 5 7 6 8 4 9 Flexi Ducting IMPORTANT For the motor to operate efficiently do n...

Page 12: ...ngehood Speed of food liquid heating Angle of ducting Scandium S bend preferred Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the...

Page 13: ...turned on Check rangehood s motor switch Ensure that there is power to the rangehood the motor is connected to the rangehood and the rangehood is switched on Check lamp switch Lamp switch should be at...

Page 14: ...ons Model SC900WRS SC900WTS Feeding Voltage 220 240V 50Hz 10 amp GPO Lamp Power Incandescent 2 x 25W Dimensions For SC900WRS Model For SC900WTS Model 272 5 0 0 5 0 0 2 5 0 900 485 311 347 5 5 0 5 5 0...

Page 15: ...product Service In the event that the failure is not due to the faults mentioned in Troubleshooting contact the customer service centre In Australia Customer Service 1300 829 066 In New Zealand Custo...

Page 16: ...41 322 Australia 8 3 4 Anzed Court Mulgrave 3170 Victoria Phone 1300 881 693 Email info scandiumappliances com au Web www scandiumappliances com au New Zealand 5 Tolich Place Henderson Auckland 0610 P...