Trouble
Possibilities
Check up
Solutions
Remarks
Compressor
does not work
Power is off
The fuse is broken
Check the fuse
Replace the fuse
If it is necessary
please contact after-
sales service for re-
pair
The connection between
plug and socket is not good
Check the socket
Repair or replace the
socket
The circuit of input and out-
put is out of use
Make sure that the-
power is on
Check the circuit with elec-
tric instrument
The thermostat knob is not in the proper position
Check the thermostat
Rotate the thermostat to
the proper position
Ask for professional
help
Compressor
Keeps on wor-
king
The temperature
inside is too high
Frost on the evaporator is
too thick
Check whether the
frost is thicker than 6-
8mm
Defrost regularly
The door is being opened
too frequently
Reduce the times of open-
ing
Too much food has been
stored at once
Take out some of the food
The temperature
inside is OK
The ambient temperature is
too high while the thermo-
stat indicates a small num-
ber
Make sure whether
the knob is indicating
at
the
“5
-
6”(or
deeper)
Adjust the thermostat
knob
The thermostat Knob
on”2
-
4”is
Better (or
proper)
The thermostat does not
work
Replace the thermostat
Ask for after-sales
service
Too noisy
The floor is not level
Make sure that the
Freezer is level
Put pad under the castors
The screw in fan or condenser is loose
The screw is loose
Rotate the fixed screw
The refrigerating circuits touch catch other
Separate them