NB: It is extremely important to ensure that the product is stable. 
It must be installed on a completely inflexible floor.

It is recommended that flooring that is not attached to the 
foundation – «floating floors» – be removed beneath the 
installation.

3.4 Requirements for floor covering 

The SCAN DSA E 

1000

 has an opening in the base plate

 (fig. 

2 - pos. 1)

.

Note!

 The opening must be covered by the accompanying steel 

plate 

(fig. 2 - pos. 12)

.

Any inflammable floor coverings should be removed from under 
the fireplace and floor plate.

3.5 Front plate

If there is inflammable flooring in front of the insert, a plate 
made of steel or some other suitably non-inflammable material 
must be used.

Contact your local building authorities regarding restrictions 
and installation requirements.

3.6 Requirements for air circulation

There must be a flow of air between the insert and the 
surround. 
This is to ensure that any build-up of heat inside the surround 
is not too great. Also that there is adequate heat output into 
the room.
 

4.0 Adaptation and setup

4.1 Painting

All surrounds are delivered unpainted!

Painting can take place the day after installation. Use latex paint. 
If you want to create some surface texture, mix some tile cement 
into the paint.

4.2 Cracks

In some instances, small cracks may appear at the joints after a 
few months’ use. These cracks can be easily repaired: 
•  Open up the crack with a tool, e.g. a screwdriver, to create 

more room for the grouting cement. 

•  Remove any dust using a vacuum cleaner. 
• 

Then inject some acrylic grout, and smooth it off using a wet, 
soapy fingertip. 

•  After 48 hours, the joint can be repainted.

5.0 Assembling the 
surround

The Scan DSA E 

1000

 consists of the following parts

 (fig. 2)

:

Part 1. 

Bottom plate x 1. -   

cat. no. 310256

Part 2.  Rear section x 1. -  

cat. no. 310257

Part 3.  Base x 1. -   

cat. no. 310258

Part 4.  Panel, left, x 1. -  

cat. no. 310259

Part 5.  Panel, right, x 1. -  

cat. no. 310260

Part 6.  Cowl x 1. -  

cat. no. 310261

Part 7. 

Cowl, top, x 1. -   

cat. no. 310262

Part 8.  Bench plate, slate, x 1. -  

cat. no. 222883

Part 9 

Grate for outdoor air, x 1. -  

cat. no. 222885

Part 10  Grate for flue pipe, x 1. -  

cat. no. 222886

Part 11  Grate for top, x 1. -  

cat. no. 222887

Part 12  Floor plate, x 1. -

Install the insert in accordance with the Installation and 
Operating Instructions provided with the product.

NB!

 We recommend test-mounting the surround before 

permanently attaching the insert to the chimney so that any 
necessary adjustments can be made.

Installation

1.  NB! Place the bottom plate 

(Fig. 4A)

 on a steady surface 

and adjust until it is standing completely level. Check that 
the safety distances meet the requirements stated in the 
operating instructions provided with the insert.

2.  Place the accompanying steel plate over the opening in the 

base plate

 (fig. 4B).

3.  Position the back wall 

(Fig. 5 A)

. Glue with acrylic adhesive.

4. Position 

the 

insert 

(Fig. 6 A)

 on the bottom plate

 (Fig. 6 B)

Do not use the adjustment screws.

5.  Put the base into place

 (Fig. 7 A)

. Glue with acrylic adhesive.

6.  Put the panels into place 

(Fig. 8 A)

. Glue with acrylic 

adhesive.

7.  Put cowl 1 into place 

(Fig. 9 A)

. Make sure that the side with the 

sharp edge is turned upwards. Glue with acrylic adhesive.

8.  Put cowl 2 into place 

(Fig. 10 A)

. The knockout must be turned 

upwards. Glue with acrylic adhesive.

9.  Put the slate tile

 (Fig. 11 A)

 into place. 

NB: 

This must not be 

glued down so as to allow for service access.

10. Place the cover 

(Fig. 12 A)

 over the outdoor air knockout since 

a supply of external air will not be used. Glue with acrylic 
adhesive.

11.  Install the flue pipe

 (Fig. 13 A)

 with the damper 

(Fig. 13 B)

 in 

accordance with the Installation and Operating Instructions 
for Scan DSA 

10

 (provided with the insert). 

12. Place the grates 

(Fig. 14 A)

 on the top of the surround. 

ENGLISH

Summary of Contents for DSA E 1000

Page 1: ...SCAN DSA E 1000 NO Installasjonsmanual 2 DK Installationsmanual 5 SE Installationsmanual 8 UK Installation Instructions 11 DE Montageanleitung 14 Figures 17...

Page 2: ...ildstedet tas i bruk m installasjonen kontrolleres av kvalifisert kontroll r Kvalifisert kontroll r kan v re et sentralt godkjent foretak eller godkjent kommunal kontrollmyndighet Det vil alltid v re...

Page 3: ...som sikkerhet for at varmeoppbygging inne i omrammingen ikke skal bli for stor Videre for at varmeavgivelse til rommet blir tilstrekkelig Se fig 1 for avstander NB Det er sv rt viktig at luft pninger...

Page 4: ...sel fig 12 A over utsparring til friskluft dersom friskluftstilf rsel ikke skal benyttes Lim fast med acryl 11 Monter r ykr ret fig 13 A med spjeldet i fig 13 B i henhold til monterings og bruksanvisn...

Page 5: ...tsen Installationen kan f rst tages i brug n r den er kontrolleret og f rdigattest er udstedt Vedr daglig brug vedligeholdelse servicearbejder osv se monterings og brugsanvisningen for indsatsen 2 0 T...

Page 6: ...stk kat nr 310258 Del 4 Vange venstre 1 stk kat nr 310259 Del 5 Vange venstre 1 stk kat nr 310260 Del 6 Kappe 1 stk kat nr 310261 Del 7 Kappe top 1 stk kat nr 310262 Del 8 B nkeplade skifer 1 stk kat...

Page 7: ...edf lgende cementspartel Forat opn det bedst muligeresultat b romramningenslibes med fint sandpapir og evt uj vnheder og skarpe kanter poleres f r man maler P f r et lag maling Bland pulveret cementsp...

Page 8: ...an installationen tas i bruk ska den inspekteras och godk nnas Se insatsensmonterings ochbruksanvisningf rdagliganv ndning underh ll service m m 2 0 Tekniska data Omramningen r anpassad till SCAN DSA...

Page 9: ...1 st art nr 310256 Del 2 Bakstycke 1 st art nr 310257 Del 3 Sockel 1 st art nr 310258 Del 4 Sidov gg v nster 1 st art nr 310259 Del 5 Sidov gg h ger 1 st art nr 310260 Del 6 K pa 1 st art nr 310261 D...

Page 10: ...s till detta F r att uppn b sta m jliga resultat b r man g ver omramningen med fint sandpapper och putsa eventuella oj mnheter och skarpa kanter innan denna m las M la sedan en g ng Blanda pulvret cem...

Page 11: ...tion work The insert comes with installation and operating instructions The product may not be used until it has been inspected and a certificate of completion has been issued For day to day use maint...

Page 12: ...art 2 Rear section x 1 cat no 310257 Part 3 Base x 1 cat no 310258 Part 4 Panel left x 1 cat no 310259 Part 5 Panel right x 1 cat no 310260 Part 6 Cowl x 1 cat no 310261 Part 7 Cowl top x 1 cat no 310...

Page 13: ...luded in the kit In order to achieve the best result the surround should be rubbed down with fine sandpaper smoothing any unevenness or sharp edges prior to painting Then apply one coat Mix the powder...

Page 14: ...sich stets Informationen vom lokalen Planungs und Bauamt sowie professionelle Hilfe einzuholen bevor Sie mit den Installationsarbeiten beginnen Der Einsatz wird mit einer Montage und Bedienungsanleitu...

Page 15: ...bgabe in den Raum gew hrleistet 4 0 Anpassung und Einrichtung 4 1 Anstrich Alle Ummantelungen werden ohne Anstrich ausgeliefert Der Anstrich kann am Tag nach der Installation vorgenommen werden Verwen...

Page 16: ...zwecken m glicht ist 10 Setzen Sie die Abdeckung Abb 12 A ber die Au enluftaussparung da kein Au enluftanschluss verwendet wird Nutzen Sie Acrylklebstoff zum Befestigen 11 Installieren Sie das Rauchga...

Page 17: ...e m l gjelder ved bruk av isolert skjermet r ykr r helt ned mot produktet Measurements given requires use of insulated covered flue pipe completely towards the product 724mm 1100mm 1100mm 1100mm 1100m...

Page 18: ...18 Fig 2...

Page 19: ...19 482 mm 1635 mm Fig 3a Fig 3b Fig 4 Fig 5 1745 mm 613 mm 613 mm A A B...

Page 20: ...20 Fig 6 Fig 7 Fig 8 Fig 9 A A B A A A...

Page 21: ...21 Fig 10 Fig 11 Fig 12 Fig 13 A A A A B...

Page 22: ...22 Fig 14 A...

Page 23: ...23...

Page 24: ...24 Krog Iversen Co AS Postboks 60 5492 Vissenbjerg Danmark Cat no 222882 January 2009...

Reviews: