Congratulations on your new ANDERSEN wood burning stove. We are confident that you will enjoy your new 

stove, especially if you follow the instructions and advice given below. 

 

An original ANDERSEN stove possesses a number plate. The registration number can be attached to the invoice 

that is to submit to the dealer in case of later complaints covered by the guarantee. 

 

In the ANDERSEN-stove you will find the following: 

 

1 oven mitten 

1 handle to operate the shaking grate 

Fitting for the flue collar 

1 set of screws and hexagon spanners 

Firelighters for the first lighting

 

 

Before the Stove is Connected to the Chimney:

 

Contact your local authorities to obtain the existing fire- and building regulations regarding the installation of 

wood burning stoves, or ask your local experts in that field, e.g. the chimney sweep, to install your stove. 

 

Security Distances: 

The  ANDERSEN  convection  stove  is  a  double-skinned  convection  stove  with  an  insulation heat shield at the 

rear, resulting in a lower surface temperature. Please consult your local experts regarding the minimum distance 

to the wall. However, we recommend that you leave enough space in order to facilitate the cleaning at the rear of 

the stove. 

 

   

The ANDERSEN radiation stoves must be connected in accordance with the regulations in force. Please consult 

your local authorities.  

 

Requirements of Flooring:

 

The stove is to be placed on a non-combustible surface, e.g. an original ANDERSEN base plate, floor tiles, or 

the like. We recommend that the base plate extends at least 150 mm from the sides and at least 500 mm from the 

front of the stove to prevent any sparks from ruining your carpet or floor.

 

 

CONNECTION TO THE CHIMNEY

 

 

We recommend that the stove is installed by an authorised dealer. From the factory the stove is prepared for top 

mounting of the flue collar, but the ANDERSEN 4 and 8 can  also be connected at the rear. 

 

The  stove  should  not  be  connected  to  a  chimney of which the inside diameter is smaller than that of the flue 

collar. The diameters of the smoke pipe and the flue collar should be the same. The gauge of the smoke pipe 

should not be less than 1.5 mm.

 

 

 The stove can be connected in the following ways: 

 

Top Discharge:

 

Turn the flue collar and tighten the fittings under the top plate by using the delivered hexagon spanner. 

 

Rear Discharge (Andersen 4 and 8):

 

Press the prestamped plate out of the reflector plate. Remove the cooking ring. Mount the flue collar from the 

outside  with  the  delivered  fittings  and  bolts.  Put  the  cooking  ring  in  the  hole  for  top  discharge  (after  having 

removed the ceramic joint).

 

Summary of Contents for ANDERSEN 8

Page 1: ...Instructions for Installation and Use SCAN ANDERSEN Stoves ENGLISH April 2003 Krog Iversen Co A S Glasvænget 3 9 DK 5492 Vissenbjerg ...

Page 2: ...eaning at the rear of the stove The ANDERSEN radiation stoves must be connected in accordance with the regulations in force Please consult your local authorities Requirements of Flooring The stove is to be placed on a non combustible surface e g an original ANDERSEN base plate floor tiles or the like We recommend that the base plate extends at least 150 mm from the sides and at least 500 mm from t...

Page 3: ... combustion chamber bricks reflector plate smoke deflector plate and service bag Place carefully the stove on the rear side Mount the legs the base or the convection plates according to sketch 1 and 2 on the last page of the manual Andersen Stoves with Soap Stone Unpack the stove Mount the soap stones according to sketch 3 on the last page of the manual MOUNTING OF THE CERAMIC SMOKE DEFLECTOR A ce...

Page 4: ...age of Wood The logs must be adapted to the size of the combustion chamber Length ANDERSEN 1 400 mm Length ANDERSEN 4 220 mm Length ANDERSEN 8 330 mm The circumference of the logs should be between 20 and 25 cm and the weight approx 0 7 kg ANDERSEN 1 and 8 may only burn wood It is also possible to use lignite briquettes in the model ANDERSEN 4 1 4 kg h or small energy briquettes In this case you m...

Page 5: ... have a fresh air intake installed Soot Free Glasses The stove is constructed to keep the glasses clean when the combustion air intake is fully opened The more you close the combustion air the greater the risk of the glass sooting up Whenever a new piece of wood is placed in the stove it is necessary to completely open the combustion air and the air intake must not be reduced until such time as th...

Page 6: ...ible change of colour to grey is caused by over firing i e you have used more wood than recommended Soap Stone The soapstones are cleaned with fine sandpaper or a dry sponge Cleaning of Glass By burning wet wood or lighting with closed dampers the doors may become more or less sooty The glasses are however easily cleaned by use of a special cleaning fluid that is available at your dealer Or as fol...

Page 7: ...t combustion Is the wood dry The shaking grate is stuck Check if a piece of wood a pin or the like is stuck Is the bar placed mounted correctly The stove s surface turns grey Over heating please refer to maintenance instructions Surface of the Stove The stove does not heat Use of moist wood The energy is used to dry the wood ...

Page 8: ...ing transport in stock during the installation or later Sooting caused by a bad chimney draught humid wood or wrong service Costs caused by extra heating costs in connection with repair Transport costs Costs in connection with dismounting and mounting of the unit The warranty is invalid If the installation or service is performed by someone other than an authorized installer or if the installation...

Page 9: ...GB 9 ...