INSTRUCTIONS FOR USE
BAFFLE PLATES
The baffle plates are located in the upper part of the combustion chamber. The plates holds back smoke, making sure it stays
inside the combustion chamber for a longer time before escaping through the chimney. This reduces the flue gas temperature as
the gases have more time to dissipate heat to the stove.
The baffle plates must be removed for sweeping; see “Maintenance”. Note that the baffle plates are made of porous, ceramic
material, and are liable to break easily. You should therefore handle them with care.
The baffle plates are subject to wear and tear and not coverec by the warranty.
COMBUSTION AIR
Combustion air is pre-heated and fed indirectly to the fire. The combustion air flow determines the heat output from your built-in
stove. At the same time, the air flow cleans the glass pane to prevent buid-up of soot. If there is a soot formation on the glass, this
is often due to the fact that the combustion air is turned too much down.
When lighting the fire, the combustion air should be fully open.
Summary of Contents for 5004 FL
Page 19: ...19 FRAMES ACCESSORY ...
Page 20: ...Scan 5004 FR Item nr 50053077 20 FRAMES ACCESSORY ...
Page 22: ...Scan 5004 FL Item nr 50053079 22 FRAMES ACCESSORY ...
Page 23: ...Scan 5004 FL Item nr 50053080 23 FRAMES ACCESSORY ...
Page 24: ...24 BRACES ACCESSORY ...
Page 42: ...42 NOTES ...
Page 43: ...43 ...