Krog Iversen & Co. A/S - DK-5492 Vissenbjerg
175
518
527
1070
914
155
Warranty conditions
All SCAN wood-burning stoves and inserts are made of first-class material and
are subject to a strict quality control before they leave the factory. However, if an
error should occur, we back all SCAN wood-burning stoves and inserts with an
extensive, five-year limited warranty.
See also the
General Instructions for Installation
delivered with your stove for
more details.
Technical info
Rated output:
7 kW
Min./max.:
3 - 9 kW
Weight:
125 - 160 kg
Connection piece, diameter:
int. 135 mm / ext. 148 mm
Production number
*
**
*To the middle of the rear outlet
**Connection piece to fresh-air intake
Distances to flammable materials
(mm)
Write the production number of your
stove here so that you have it at hand
in case you need to contact us.
You can choose between several floor plates in different shapes
and dimensions for your stove. Furthermore, you can have a
specially made, shaped floor plate for the SCAN 37-2, which is
to be placed in front of the stove. Please contact your local aut-
horities concerning the security distances needed.
SCAN 37-2
200
500
300
800
800
Base plate
Radiation area
Data for calculation of the chimney
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2
Flue gas
tempera-
ture
oC
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
oC
6
Minimum
draft
Pa
7
0,8
Minimum
draft
Pa
37-2
150
-
-
-
7
300
14
11
With closed doors
With open doors
Column 2 and 5 show the flue gas temperature in the connecting adaptor
Column 3 and 6 show the lowest/minimum draft in Pa by rated value