C
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005031.idw
91005031
Montage konvektionsstudse
22-05-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005017.idw
91005017
Afmontage dækplader i topplade
19-03-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005015.idw
91005015
Afmontage konvektionsdækplader
19-03-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
1
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005018.idw
91005018
Konvektionshuller i topplade
19-03-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
2
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
I:\Udvikling\TEGNING\DSA 11\90084033.idw
90084033
Montage af konvektionsstudse
05-10-2009
BC
Scan DSA 11
VÆGT:
AREAL:
N/A
N/A
C
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005031.idw
91005031
Montage konvektionsstudse
22-05-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005015.idw
91005015
Afmontage konvektionsdækplader
19-03-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005016.idw
91005016
Hul i svøb for konvektion
19-03-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005017.idw
91005017
Afmontage dækplader i topplade
19-03-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
21
FITTING THE CONVECTION CONNECTION PIECES
Convection connection pieces Ø149 mm
To dismount the cover plates for the convection adaptors, use an slotted screwdriver as shown below. Tilt the screwdriver and
loosen the cover plates.
Fastening points
Cassette without cover plates
6 x Allen screws M4x10
6 x Flange nuts M4
Fit and tighten the cassette, see "Fitting the cassette".
When the cassette has been tightened, fit the convection connection pieces. Fit these and tighten them through the hole for the
flue connection piece.
FITTING WITHOUT THE CONVECTION CONNECTION PIECES
The cover plates in the top plate can be removed in order to reduce the temperature on the wall above the insert. If the insert is
built into an existing fireplace the cover plates are not to be removed.
To dismount the cover plates for the convection air, use a slotted screwdriver as illustrated below. Tilt the screwdriver down-
wards and loosen the cover plate. Fit and tighten the cassette, see "Fitting the cassette".
Cassette without cover plates
in the top plate
(ACCESSORY)