Standard templates
Whenever possible, we recommend using templates for mounting transmis-
sion originals. Besides making batch scanning more efficient and ensuring
proper alignment of all originals, using the templates minimizes the use of
tape directly on the mounting plate, prolonging the life of the plate.
A set of several different templates is supplied with the scanner. Additional
templates in any of the formats are available from your ScanView dealer.
MOUNTING ORIGINALS IN A TEMPLATE
• Choose the template that matches the size of your originals and ensure that
the top surface is clean so that the tape can adhere properly.
• If the number of originals to be mounted is less than the number of
cut-outs in the template, mount the originals in the number sequence
marked on the template. Note that the highest scan resolution is obtained
in the center part of the scanner bed.
• Place the originals with the emulsion side down and the top edge towards
the coded end of the template.
• Using a good quality lithographic tape, tape the original to the template on
two sides.
Handling originals and mounting plates
5•4
ScanMate F10 • Operator’s Manual
24 x 36 mm
6 x 6 cm
4" x 5"
35-mm strips, vertical
35-mm strips, horizontal
6 x 7 cm
Reflection
A set of seven templates for
various common original formats is
supplied with the scanner.
Additional templates are available
from your ScanView dealer.