13
Operation
SC 1500 - Doc. No. 018522-000/03-025
GB
Setting dimension detection accuracy (3D-function)
To set the short side detction accuracy, follow the previous
instruction (
“Setting dimension detection accuracy (DD-function,
short side)” on page 12
).
The
3D
function must be in use.
1)
Press
SET
“3d” appears on the display.
2)
Press the numerical key
1
(increase) or
0
(decrease) to select the desired detection accuracy. The range is
4-8 mm.
3)
Press
ST/CL
.
Setting note density (IP)
When the
IP
function is off, “DE X” appears on the display, the
density range can be set according to the bank notes to be counted.
Eight levels of note density are provided. The factory setting is level 4.
Note!
The
IP
function will automatically handle almost any kind of
document and should only be switched off
when documents in
specific condition is to be counted (for example extremely light and/
or extremely dark documents mixed in the same bundle).
1)
Press
SET
several times until “dE” appears on the display.
2)
Press numerical key
1
(increase) or
0
(decrease) to select proper
density level:
– DE 1-2: thin, light colored or new note/document;
– DE 3-5: note/document with color between light and dark;
– DE 6-8: thick, dark colored, old or dirty note/document.
3)
Press
ST/CL
.