15
PRODUCT SPECIFICATIONS, STANDARDS AND REGULATIONS
General Information
Description
SCAME DC WALLBOX, 25 kW, CE, 1 or 2 output connectors, CCS type 2 and CHAdeMO, 4.5 m cables, 7” TFT touch
display, RFID reader, EMC Class A
Technical Data
Output Configurations
Configuration 1 (206.D91-E10):
CCS type 2
Configuration 2 (206.D91-E11):
CHAdeMO
Configuration 3 (206.D91-E12):
CCS type 2+ CHAdeMO
not
simultaneously
Output power
Peak 25 kW Continuous 25 kW
Number of EV Connectors
(CCS type 2) 1 piece
(CHAdeMO) 1 piece
(CCS type 2) 1Pc.
(CHAdeMO)
1Pc.
Number of AC Socket Outlets
None
Cable Length
4.5 m
Min Output Voltage (Vout)
150 V DC
Max Output Voltage (Vout)
(CCS type 2) 1000 V DC
(CHAdeMO) 500 V DC
(CCS type 2) 1000 V DC
(CHAdeMO) 500 V DC
Maximum Output Current (Iout)
60 A DC
AC Input power connection
3P + N + PE
Supply Voltage
400 V AC +/- 10% (50 Hz or 60 Hz)
AC Power Supply
Nominal 27 kW, 40 A / Peak 27 kW, 40 A
Efficiency
94% at nominal power
Mechanical dimensions
794 mm (H) x 594 mm (W) x 252mm (D)
Weight
Approximately 70kg excluding the cables
Ingress Protection rating
IP54
Impact Resistance rating
IK10
Ambient temperature
-30 to +45 ˚C (derating above +45°C)
Storage temperature
-30 to +60 ˚C
Altitude
2500 m max
Humidity
5% to 95% non condensating
Acustic noise
< 55dB in all directions
Network Connections
GSM 3G/4G modem
Ethernet port 1 x LAN 10/100Mbps
WiFi IEEE 802.11b/g/n, Access Point (AP), Station (STA)
Guaranteed Network Bandwidth
3G up to 42Mbps, 4G up to 150Mbps
Ethernet 10Mbps
Authentication Method
RFID ISO1443A MiFare Classic, MiFare Plus, MiFare DESFire
HMI
7” TFT touch display with adjustable backlight Motion and ambient light sensors
Communication
OCPP 1.6 JSON