background image

15

PRODUCT SPECIFICATIONS, STANDARDS AND REGULATIONS 

General Information

Description

SCAME DC WALLBOX, 25 kW, CE, 1 or 2 output connectors, CCS type 2 and CHAdeMO, 4.5 m cables, 7” TFT touch 

display, RFID reader, EMC Class A

Technical Data

Output Configurations

Configuration 1 (206.D91-E10):

CCS type 2

Configuration 2 (206.D91-E11):

CHAdeMO

Configuration 3 (206.D91-E12):

 

CCS type 2+ CHAdeMO

 

not 

simultaneously

Output power

Peak 25 kW Continuous 25 kW

Number of EV Connectors

(CCS type 2) 1 piece

(CHAdeMO) 1 piece

(CCS type 2) 1Pc.

 

(CHAdeMO)

 

1Pc.

Number of AC Socket  Outlets

None

Cable Length

4.5 m

Min Output Voltage (Vout)

150 V DC

Max Output Voltage (Vout)

(CCS type 2) 1000 V DC

(CHAdeMO) 500 V DC

(CCS type 2) 1000 V DC

(CHAdeMO) 500 V DC

Maximum Output Current (Iout)

60 A DC

AC Input power connection

3P + N + PE

Supply Voltage

400 V AC +/- 10% (50 Hz or 60 Hz)

AC Power Supply

Nominal 27 kW, 40 A / Peak 27 kW, 40 A

Efficiency

94% at nominal power

Mechanical dimensions

794 mm (H) x 594  mm (W) x 252mm (D)

Weight

Approximately 70kg excluding the cables

Ingress Protection rating

IP54

Impact Resistance rating

IK10

Ambient temperature

-30 to +45 ˚C (derating above +45°C)

Storage temperature

-30 to +60 ˚C

Altitude

2500 m max

Humidity

5% to 95% non condensating

Acustic noise

< 55dB in all directions

Network Connections

GSM 3G/4G modem

Ethernet port 1 x LAN 10/100Mbps

WiFi IEEE 802.11b/g/n, Access Point (AP), Station (STA)

Guaranteed Network Bandwidth

3G up to 42Mbps, 4G up to 150Mbps

Ethernet 10Mbps

Authentication Method

RFID ISO1443A MiFare Classic, MiFare Plus, MiFare DESFire

HMI

7” TFT touch display with adjustable backlight Motion and ambient light sensors

Communication

OCPP 1.6 JSON

Summary of Contents for 206.D91-E10

Page 1: ...BE D Series User Manual...

Page 2: ...n strategies enabled at the time of commissioning PRODUCT DESCRIPTION AND PRODUCT CODES Part Numbers 206 D91 E10 support CCS type 2 charging method only Part Numbers 206 D91 E11 support CHAdeMO chargi...

Page 3: ...to connect the vehicle Adaptors or conversion adapters are not allowed to be used either ACCESS CONTROL AND IDENTIFICATION MODES Starting a charging session on BE D wallbox can be done by selecting d...

Page 4: ...ged in two possible ways Locally via Scame Management System Net Local Remotely via an OCPP Central Station Net OCPP Authorization via user cards Net Local In this case the RFID card reader is enabled...

Page 5: ...ing platforms such as billing charger reservations and remote identification via a mobile app are supported Note that registration of authorized users must be done via the central station platform and...

Page 6: ...rience the display backlight is dynamically adjusted according to the data sensed by the motion and ambient light sensor as it will be explained in the following Image 6 depicts theTFT touch display T...

Page 7: ...immediately increasing the display brightness which level is still being adjusted in discrete steps depending on the ambient light Alternatively the operational mode can be entered by directly tappin...

Page 8: ...start the charge The RFID card needs to be presented in front of the rfid reader otherwise This can have either one or two connectors depending on the specific model of the unit 206 D91 E10 shows CCS...

Page 9: ...9 shows the language selection screen among with the supported languages Image 10 RFID reader display screen Image 11 Languages Image 12 Preparing CHAdeMO connector unplugged...

Page 10: ...om this point on Instead with older CHAdeMO EVs supporting only the first release of the protocol i e CHAdeMO version 0 9 1 the plug presence into the EV inlet can not be automatically detected Becaus...

Page 11: ...o the user which include the status of the plug reserved charge in progress charge completed the State of Charge of the battery reported by the EV SoC 0 to 100 the amount of energy already delivered t...

Page 12: ...BE D SERIES 12 Image 17 detail 1 Image 18 detail 2 Image 19 error message Should any error or fault occur during charging a message similar to the one shown by image 19 will be posted...

Page 13: ...d by the end user or manually if the end user so decides In the second case a dedicated push button needs to be presses to confirm the decision See image 20 Image 21 stopping If the unit operates in F...

Page 14: ...th a built in wireless router that provides mobile 4G LTE 3G 2G andWiFi connectivity as well For mobile 4G LTE 3G 2G communication a SIM card needs to be inserted into the router See image 22 The SIM...

Page 15: ...m Output Current Iout 60 A DC AC Input power connection 3P N PE SupplyVoltage 400V AC 10 50 Hz or 60 Hz AC Power Supply Nominal 27 kW 40 A Peak 27 kW 40 A Efficiency 94 at nominal power Mechanical dim...

Page 16: ...ng 2011 65 EU RoHS2 EMC Emission Class A IEC 61000 6 4 EMC Immunity IEC 61000 6 2 industrial environments IEC 61851 1 IEC 61851 21 2 IEC 61851 23 IEC 61851 24 IEC 61439 7 IEC 60529 REACH Regulation UN...

Page 17: ...WARRANTY THIS LIMITEDWARRANTY IS EXPRESSLY LIMITEDTOTHE ORIGINAL PURCHASER PURCHASER OFTHE BE D SCAME Charger CHARGING STATION DISPOSAL INSTRUCTIONS Implementation of Directive 2012 19 EU onWaste Ele...

Page 18: ...BE D SERIES 18...

Page 19: ...19...

Page 20: ...VIA SPIAZZI 45 24028 PONTE NOSSA BG ITALIA TEL 39 035 705000 FAX 39 035 703122 emobility scame com e mobility scame com ZP91188 EN 1 e mobility scame com...