background image

© 2007.  Scaletron Industries Ltd. Plumsteadville, PA  Scaletron.  Scaletron Sets The Standard In Corrosion Resistance.  Model 1099, Model 2305, Model 2306, Model 2307, Model 
2310, Model 2330, Model 2350, Model 2352, Model 2353, Model 3001, Model 3002, Model 3001 SI, Model 3002 DI, Model 3003, Model 3004, Model 3005, Model 3006, Model 3050-1, 
Model 3050-2, Model 4010, Model 4020, Model 4021, Model 4030, Model 4040,  Model 4042, Model 4042WB,Model 4041, Model 4042, Model 4042 WB, Model 5305, Model 5305-2, and 
ProGram Guide are trademarks of Scaletron Industries Ltd.  Total Electronic System is a service mark of Scaletron Industries Ltd.  All Rights Reserved.  .PRINTED IN U.S.A.  JULY 2007.

 

VII. Board 

Diagram: 

 

Summary of Contents for 4042

Page 1: ...e P O Box 365 Plumsteadville PA 18949 USA Toll Free 1 800 257 5911 USA Canada Phone 1 215 766 2670 international Fax 1 215 766 2672 E mail info scaletronscales com Website www scaletronscales com OEM Manual MODEL 4042 AND 4042WB 3 DIGIT SECONDARY SPILL CONTAINMENT SCALE ...

Page 2: ...hould be followed Carefully inspect all packing material before discarding to prevent the loss of accessories mounting hardware spare parts or instructions TABLE OF CONTENTS PAGE I GENERAL DESCRIPTION 1 II SPECIFICATIONS 1 2 III ASSEMBLY AND START UP 2 IV GENERAL USE INSTRUCTIONS 3 V CALIBRATION PROCEEDURE 3 4 VI TROUBLESHOOTING 4 VII BOARD DIAGRAM 5 6 I General Description The Model 4042 and 4042...

Page 3: ...d inspect for damage bent metal broken wires cracks in indicator etc Any shipping damage must be reported to carrier Step 2 Place the scale on a solid dry and even surface Clear the area of all debris where the scale base will be placed VERY IMPORTANT If Model 4042WB make sure that expandable bladder has room and clearance to expand without coming into contact with any other objects that may cause...

Page 4: ...et Weight contents in the tank If this is the case you will use this procedure Load on your full tank and attach any equipment that affects the weight on the scale Turn the black tare knob on the front of the indicator until it reads the known NET WEIGHT weight of contents only on the indicator Clockwise will increase the readings and counter clockwise will decrease the readings When the weight is...

Page 5: ...5 Adjust tare knob on front of weigh meter until scale reads zero with no weight on platform Adjust R 22 to set the 4mA reading to 0lbs 6 Place a known weight on the disc as close to center as possible Weight should be equal to of capacity or greater 7 Adjust R 15 until display reads weight of test weight on scale disc 8 To complete calibration of 4 20mA output adjust R 19 for proper 20 mA adjustm...

Page 6: ... Model 3001 SI Model 3002 DI Model 3003 Model 3004 Model 3005 Model 3006 Model 3050 1 Model 3050 2 Model 4010 Model 4020 Model 4021 Model 4030 Model 4040 Model 4042 Model 4042WB Model 4041 Model 4042 Model 4042 WB Model 5305 Model 5305 2 and ProGram Guide are trademarks of Scaletron Industries Ltd Total Electronic System is a service mark of Scaletron Industries Ltd All Rights Reserved PRINTED IN ...

Page 7: ...02 Model 3001 SI Model 3002 DI Model 3003 Model 3004 Model 3005 Model 3006 Model 3050 1 Model 3050 2 Model 4010 Model 4020 Model 4021 Model 4030 Model 4040 Model 4042 Model 4042WB Model 4041 Model 4042 Model 4042 WB Model 5305 Model 5305 2 and ProGram Guide are trademarks of Scaletron Industries Ltd Total Electronic System is a service mark of Scaletron Industries Ltd All Rights Reserved PRINTED I...

Reviews: