SCALE-TEC GRAIN CART Instructions Manual Download Page 7

 

 

Junction Box Mounting

 

7600414 REVA

 

 

Page 7 

 

JUNCTION BOX MOUNTING 

Four Hole Junction Box 

The junction box is water resistant, not water-proof. It should be mounted to avoid submersion during 
wetweather and to avoid physical abuse. The junction box can be mounted on the frame of the grain 
cart. All load cell cables must reach the J-Box. Install by removing the double sided tapebacking and 
apply to cleaned surface. 

Connect Load Cell and Indicator “J-Box” Cable 

1. Route front and rear load cell cables to J-box location.

 

Make sure they are not bound or pinched. Cable tie 
(customer provided) load cell cables in place. 
2. Insert load cell and J-box cables through each of the 
water-tight strain-reliefs. 
3. Remove each terminal block from the J-box. 
4. Connect wires of the same color to the same terminal 
block as shown above. See instructions below. 
5. Install terminal block into the J-box as shown (location 
not important). 
6. Tighten nuts on the water-tight strain-reliefs. 
7. Assure that gasket is properly installed in the cover. 
8. Attach cover using 4 screws (provided). 

 
Installing Wires into Terminal Block 

1. Open levers 90º to locked position. 
2. Insert individual wires into terminal. 
3. Close lever. 
4. Tug wire to assure solid connection. 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for GRAIN CART

Page 1: ...7600414 REVA GRAIN CART RETROFIT DEMCO TRACKS SCALE SYSTEM Instructions...

Page 2: ...INTRODUCTION 3 Charging Battery and Welding 3 SCALE BRACKET AND LOAD CELL MOUNTING INSTALLATION 4 Scale Installation 4 JUNCTION BOX MOUNTING 7 Four Hole Junction Box 7 INDICATOR MOUNTING 8 RAM MOUNT...

Page 3: ...t follows NEVER OPERATE WITHOUT ALL COVERS SHIELDS AND GUARDS IN PLACE KEEPHANDS FEET AND CLOTHING AWAY FROM MOVING PARTS FAILURE TO HEED MAY RESULT INSERIOUS PERSONAL INJURY OR DEATH Some covers and...

Page 4: ...in Cart to provide support in the event of a jack failure or lifting device failure Only install one side at a time Lifting both sides simultaneously may be too unstable and result in serious injury o...

Page 5: ...wivel shaft iii Unbolt and remove the pintle receiver from the vertical adjustment hitch IMPORTANT For Digi Star load cells arrow sticker must be pointed up For Weigh Tronix weigh Bars TOP sticker mus...

Page 6: ...eigh Bars TOP sticker must be positioned to the top ii Install the swivel collar onto the load cell and retain it with the existing hardware iii Install the vertical adjustment hitch onto the load cel...

Page 7: ...tion Make sure they are not bound or pinched Cable tie customer provided load cell cables in place 2 Insert load cell and J box cables through each of the water tight strain reliefs 3 Remove each term...

Page 8: ...tall to indicator bottom panel Power Connection The power cable should be connected directly to a vehicle battery or regulated power supply The scale end of the power cable is attached to the J901 con...

Page 9: ...ghed needs to be at least full for us to adjust calibration Check operator s manual or give us a call at 1 888 962 2344 Erratic weights The following process needs to occur in an effort to eliminate o...

Reviews: