background image

10 

Quick Start Guide SCAIME: 

NUSG-eNodTouch-MS-FE_196776_D.docx 

 

Confirm that the installation gasket is attached to eNodTouch unit and then place the unit into the Panel from the front. 

 

It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to repelling water. 

 

 

Press the installation fastener hooks securely into the insertion slots on eNodTouch. 

 

Tighten the installation fasteners with a screwdriver. There are two insertion slots on both the top and bottom. 

 

NOTE: 

When installing to panel cut-out for monochrome model (eNodTouch-S) the eNodTouch-S Panel Cut-out Adapter (

ref. 

632156

) is required. In this case, before placing eNodTouch-MS into the Panel: 

-

 

Remove the gasket from this product 

-

 

Attach the eNodTouch-S Panel Cut-out Adapter to this product: 

 

1- eNodTouch-S Panel Cut-out Adapter 

 

Electrical powering 

 

Supplying a power voltage other than that specified will damage the power source and the unit. 

 

When the FG terminal is connected, be sure the wire is grounded. 

 

 

24V 

0V 

FG 

Grounding Terminal 

connected 

to eNodTouch chassis 

Conductor type 

Simple Wire: 0.75 to 1.5mm2 

Stranded Wire: 0.75 to 1mm2 

 

 

RS485 interface for connection to eNod4 

 

The serial interface is not isolated. Always connect the SG (Signal Ground) of the unit to the connected device. 

 

SG (Signal Ground) and FG (Frame Ground) are connected internally 

Summary of Contents for eNodTouch-MS

Page 1: ...SCAIME SAS Technosite Alt a 294 Rue Georges Charpak 74100 JUVIGNY FRANCE T l 33 0 4 50 87 78 64 www scaime com eNodTouch MS Ecran tactile pour multiples contr leurs eNod4 Touch screen for multiple eN...

Page 2: ...4 Installation d eNodTouch 5 Alimentation lectrique 5 Interface RS485 pour la connexion l eNod4 6 Entrer dans le mode Offline en fonctionnement 7 English Presentation 8 Installation 9 Installation re...

Page 3: ...rature humide 39 C ou moins Poussi re 0 1 mg m ou moins niveaux non conductifs Temp rature de stockage 20 60 C Structure IP65F Type 1 Type 4X Utilisation l int rieur seulement Type 13 sur le panneau...

Page 4: ...ins 100 mm d autres quipements Lors de l installation eNodTouch sur le panneau d une armoire ou un coffret assurez vous que la temp rature et l humidit ambiante sont compatibles avec les caract ristiq...

Page 5: ...s et assure l tanch it du montage Positionner les crochets des l ments de fixation dans les fentes d eNodTouch pr vues cet effet Visser les l ments de fixation avec un tournevis Il y a deux fentes d i...

Page 6: ...85 tiquette Descriptif CSB Send Possible B CSA Send Possible A ERB Data Terminal Ready B ERA Data Terminal Ready A SG Signal Ground RDB Receive Data B RDA Receive Data A SDB Send Data B SDA Send Data...

Page 7: ...he de l cran pendant au moins 3 secondes juste apr s l allumage de l cran En fonctionnement Toucher le coin sup rieur droit suivi du coin inf rieur gauche ou le coin sup rieur gauche suivi du coin inf...

Page 8: ...Non condensing wet bulb temperature 39 C or less Dust 0 1 mg m or less non conductive levels Storage temperature 20 to 60 C Structure IP65F Type 1 Type 4X Indoor Use only Type 13 on the front panel wh...

Page 9: ...ranges Surrounding air temperature 0 to 50 C Ambient humidity 10 to 90 RH Wet bulb temperature 39 C max When installing eNodTouch on the panel of a cabinet or enclosure Surrounding air temperature ind...

Page 10: ...S the eNodTouch S Panel Cut out Adapter ref 632156 is required In this case before placing eNodTouch MS into the Panel Remove the gasket from this product Attach the eNodTouch S Panel Cut out Adapter...

Page 11: ...tch 4 bit on the rear of the RS 422 485 type Factory default settings are all set to OFF no terminating resistor Entering Offline mode when Operating At Power ON Touch the upper right corner or upper...

Page 12: ...ng Touch the upper right then bottom left corners or the upper left and bottom right corners of the panel within a 40 pixel area within 0 5 seconds When the system menu is displayed touch the Offline...