Nod3-

D

 : User’s instructions 

165 752-A 

23/23 

12.2.7  Target weight and inflight weight 

The  ‘fine  feed’  ddisabling  occurs  when  the  gross  measurement  decreasing  is  superior  to  the  (target 
weight – inflight level)
 level. The inflight weight value allows therefore to quantify the weight of product 
that carries on falling after the output inhibition and so to avoid a systematic overoload. 
This value can be automatically adjusted, the correction amplitude is affected by a percentage that can be 
configured.  It  is  also  possible  to  have  a  stronger  correction  (x  3)    as  the  result  is  outside  the  fixed 
tolerances (cf. §12.29). 

(

 

reference weight – gross measurement 

  (target weight – inflight level)) 

12.2.8  Final stabilization time 

This  timer  corresponds  to  the  minimal  necessary  duration  for  the  stabilization  of  the  weight  before  the 
determination of the result and the control of tolerances. 
When it is over, the ‘motion time out’ timer begins. If the stability can not be found within this duration, the 
dosing result compared to the tolerances is equal to the last gross measurement value. 

12.2.9  Tolerances 

The  dosing  result  is  compared  to  2  limit  values  in order to check that it is included within an acceptable 
range.  

∗ 

a high tolerance (tolérance +) or tolerance in excess :  

 

if the difference |(target weight – dosing result) > tolérance + |  
where  (target  weight  –  dosing  result)  <  0,  the  ‘out  of  tolerances’  and  ‘dosing  failure’ 
outputs are activated. 

∗ 

a low tolerance (tolérance -) or tolerance in default :  

 

if the difference |(target weight – dosing result) > tolérance - |  
where  (target  weight  –  dosing  result)  >  0,  the  ‘out  of  tolerances’  and  ‘dosing  failure’ 
outputs  are  activated.  If  the  ‘use  FF  if  out  of  low  tolerance  -’  is  active,  the  fine  feed  is 
restarted. 

12.2.10 End of cycle waiting time 

This  timer  is  triggered  after  ther  control  of  tolerances  or  after  the  end  of  the  reloading  phase  if  the 
reloading mode is set to ‘at the end of the cycle’.  

12.2.11 Effective end of the cycle 

When  the  ‘end  of  cycle  wating  time’  is  over,  an  output  assigned  to  the  ‘cycle  in  progress’  function  is 
disabled  and  the  statistic  variables  (number  of  cycles,  average  value,  running  total  and  standard 
deviation) are updated. 
If  the  reloading  mode  is  set  to  ‘at  the  end  of  the  cycle’  and  if  the  gross  measurement  is  inferior  to  the 
‘reloading min level’, the reloading phase starts (cf. §12.1.1) and the effective end of the cycle (‘cycle in 
progress’
 inhibition and statistic variables update) occurs when this phase is over. 

12.3  Digital inputs utilization 

12.3.1  Start cycle 

If  all  the  starting  conditions  are  respected  (cf.  §12.2.2),  a  rising  or  a  falling  edge  (depending  on  the 
configured  logic)  on  this  input  causes  a  new  dosing  by  unloading  cycle  to  be  started  else  an  error  is 
reported by a ‘dosing failure’ output and into a read-only diagnostic register. 

12.3.2  Suspend current cycle 

This input function has got two different effects : 

∗ 

if  the  ‘relaunch  cycle  if  suspended’  option  is  inactive :  this  edge-active  input  causes  the 
feeding cycle to be stopped inhibiting the different outputs involved. 

∗ 

else the cycle is suspended until a new request of starting the cycle that causes the cycle to 
continu from its last step. 

12.3.3  Stop cycle 

This edge-active input causes the feeding cycle to be stopped inhibiting the different outputs involved. 

 

 

Summary of Contents for eNod3-D

Page 1: ...e eN No od d3 3 D D D Di ig gi it ta al l d do os si in ng g c co on nt tr ro ol ll le er r eNod3 D User s instructions 165 752 A 1 23 User s instructions...

Page 2: ...mode 12 7 4 Feeding mode in dosing processes 13 8 SET POINTS 13 9 FILTERS 13 10 TRANSMITTER FUNCTIONING MODE 14 10 1 Measurement reading request 14 10 1 1 Single measurement transmission 14 10 1 2 Con...

Page 3: ...12 2 2 Verification of the available product quantity 22 12 2 3 Start delay 22 12 2 4 Coarse feed effect neutralization time 22 12 2 5 Fine feed level 22 12 2 6 Fine feed effect neutralization time 2...

Page 4: ...ts transmitter dosing by filling dosing by unloading eNod3 D is equiped with RS485 422 RS232 and CANbus outputs supporting ModBus RTU SCMBus and CANopen protocols Each module is also provided with 2 d...

Page 5: ...ltage 0 3 VDC high level voltage 9 28 VDC current at high level 10mA 24V mA insulation voltage 2500 Vrms Logical outputs number 4 type opto insulated static relays max current 40 C 0 4 A max voltage i...

Page 6: ...t the power supply is correctly connected 2 2 Connection to load cell s eNod3 D supplies power to the load cells 5 VDC Up to four 350 load cells can be connected in parallel eNod3 D allows the use of...

Page 7: ...ection to a detector connection to a push button PB 2 3 2 Digital outputs Opto insulated inputs characteristics high level 9 to 28VDC Consumption 10mA 24VDC low level 0 to 3 VDC Opto insulated outputs...

Page 8: ...eception RB inverse reception For an RS485 half duplex communication just connect the TB and TA pins and remove the corresponding jumper OFF For an RS422 or RS485 full duplex communication use the fou...

Page 9: ...is based on the master slave structure however it allows to transmit measurements continuously without collision management on the line This operating mode is only available in transmitter functioning...

Page 10: ...Physical calibration using known references on the load cell This type of calibration can be done with 1 2 or 3 known loads Theoretical adjustment by setting the load cell sensitivity and a correspon...

Page 11: ...no effect tare one or the other or both inputs can be assigned to the tare function The tare acquisition is conditioned by a stability criterion that can be changed or inhibited Depending on the choos...

Page 12: ...le set points cf 8 Output 1 is assigned to set point 1 output 2 to set point 2 output 3 to set point 3 and output 4 to set point 4 Motion The outputs can be assigned to copying measurements stability...

Page 13: ...nd order band stop filter self adaptive filter Filtering related to the A D conversion rate the signal resolution is related to the conversion rate The conversion rate might be choosen as low as possi...

Page 14: ...lar positive analog signal only or bipolar positive or negative analog signal 10 1 Measurement reading request 10 1 1 Single measurement transmission Regarless of the communication protocol in use The...

Page 15: ...5 This is only possible using standard or fast SCMBus The request can apply to gross measurement net measurement measurement in A D converter points While the input is kept at the right level a serie...

Page 16: ...ess is entirely managed by eNod3 D and especially thanks to its four digital outputs allowing to monitor the different phases of the cycle and to indicate errors Fig 6 and 7 shown below represent grap...

Page 17: ...ion of a start cycle command or the activation rising or falling edge depending on the logic of a digital input assigned to this function the filling cycle starts as soon as the start delay has elapse...

Page 18: ...minimal value If it is not the case an output assigned to dosing failure or flow rate failure is set and the cycle is suspended if the cycle recovery option is active else it is stopped The flow rate...

Page 19: ...s are activated If the use FF if out of low tolerance is active the fine feed is restarted If the updated result is out of tolerances and if the automatic inflight correction option is active the infl...

Page 20: ...ight in loss from a tank equiped with a load cell In this functioning mode the dosing process is entirely managed by eNod3 D and especially thanks to its four digital outputs allowing to monitor the d...

Page 21: ...eloading holding time 2 start delay 3 motion time out 4 coarse feed effect neutralization time 5 fine feed effect neutralization time cycle in progress reloading dosing result available start cycle Fi...

Page 22: ...ined by two parameters a time interval if 0 the flow rate control is not used a minimal weight variation 12 2 2 Verification of the available product quantity At every cycle start eNod3 D checks that...

Page 23: ...ce target weight dosing result tol rance where target weight dosing result 0 the out of tolerances and dosing failure outputs are activated If the use FF if out of low tolerance is active the fine fee...