7 OUTPUTS
FUNCTIONING:
Each output can function in positive or negative logic individually.
7.1 Assignment of outputs:
Function
Operating mode
Transmitter
Checkweigher
Peak
control
set point
●
●
●
motion
●
●
●
defective
measurement
●
●
●
checkweigher result
available
●
cycle in progress
●
●
inputs image
●
●
●
level on request
●
●
●
7.2 General
functions:
- set point:
outputs can be assigned to copying the state of set points. Output 1 is assigned to set
point 1 and output 2 to set point 2.
-
motion
: outputs can be assigned to copying measurement stability.
-
defective measurement
: outputs can be assigned to copying measurement faults. These faults
are also coded in the status word attached to the measurements. There are 4 of them:
∗
outside converter range on the positive side.
∗
outside converter range on the negative side.
∗
outside capacity on the positive side.
∗
outside capacity on the negative side.
-
inputs image
: outputs can be assigned to copying inputs, either using the same logic or inverting
the state of the input (negative logic). Output 1 is assigned to input 1 and output 2 to input 2.
-
level on request:
outputs state is driven by master requests on the communication bus. The
activation duration can be modified.
7.3 Functions attached to an operating mode:
See corresponding sections for a complete description