15
6 Jumper Configuration
On the IP-OPTODA16CH4 the desired DAC output voltage range is configured by a 3-pin jumper field.
The configured DAC output voltage range applies to all four DAC channels.
Jumper Configuration:
Voltage range 0V to +10V :
J1 1-2 installed
Voltage range +/- 10V :
J1 2-3 installed
Industry
Pack
I/O
Interface
Industry
Pack
logic
Interface
J1
3
2
1
Figure 6-1: Jumper Configuration for Output Voltage Range IP-OPTODA16CH4
Factory configuration is 0V to +10V output voltage range for all DAC channels.