7-
Route the wires
(U)
(with connector) and
(V)
(without connector) from the blower
motor through the wire grommet of the thermal switch bracket (B). Connect the wire
with connector (U) on one of the two poles of the thermal switch.
For next steps, see the wiring diagram
8-
With a wire connector (Marrette)
(M1)
, join the white wire of cable
(T)
to the wire
(V)
of the blower motor
.
9-
Connect the supplied wire
(L)
to the second pole of the thermal switch.
10-
With a wire connector (Marrette)
(M2)
, join the other end of wire
(L)
to the white wire
of cable
(S).
11-
With a wire connector (Marrette)
(M3)
, join the black wire of cable
(S)
to the black
wire of cable
(T).
12-
Using a wire connector (Marrette)
(M4)
, join the ground wires of cables
(S)
and
(T)
to
the wire
(K)
provided. Then attach the star shaped connector on the junction box
(C)
using the screws
(I)
and the nut
(J)
.
Summary of Contents for AC01387