4.2.3. Electrical specifications
Recommended electrical specifications from -40°C to 75°C.
Parameter
Min.
Typ.
Max.
Units
Conditions
Operating voltage
9
36
VDC
Power consumption
3
W
Ekinox-A / E
5
W
Ekinox-D
Allowable Input Voltage Ripple
400
mV p-p
Under voltage lock out
8,5
V
Turn on threshold
7,5
V
Turn off threshold
Galvanic Isolation
200
VDC
VIN+ to Mechanical Ground
VIN- to Mechanical Ground
4.3. Main connector
The main connector is mainly used to configure the device and read data from it. It features the following
interfaces:
●
One serial interface that supports full-duplex operations at up to 921 600 bps. It can be configured to
operate as an RS-232 or RS-422 interface by pulling down the pin 2.
●
One CAN 2.0A/B interface that supports up to 1 Mbit/s data rate used to output data.
●
One Ethernet 100BASE-T interface for device configuration, FTP access and virtual UDP or TCP/IP
serial ports.
●
One synchronization input / event marker signal for clock synchronization or to output data on a
signal event.
●
Two Synchronization output signals for time stamping and to trigger some equipment.
4.3.1. Connector specifications
The main connector uses a 19 ways female AluLite Fischer connector which is compatible with the Fischer
Core Series. To avoid misconnection the main connector uses the keying code 11. The exact receptacle
reference is: AL1731-DBPU-104-A092PB11-12G13
This 104 size connector mates with following Core Series and AluLite plugs: Don't forget that these two
references don't include the cable clamp sets. Other compatible references, with possibly right angle design
can be found.
●
AL1731-S-104-A092SR11-11 (AluLite version)
21/46
Figure 4.6: Main plug
Figure 4.5: Main receptacle front view