Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

        This product is Double Insulated and              
        does not require connection to an Earth circuit.

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without your 
knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the 
connections.

This product is not suitable for dimming.

household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling 
advice.

These products should not be fitted to PIR circuits or short 
duration timed switches.

This product is IP65 rated

Specification

Layout

Wiring - Non-Maintained

Check that...

block.

Voltage: 240V ~ 50Hz

IP rating: 65         

Operating Temperature : 

-5˚C

 to 

50˚

C

Maximum Operating Humidity  : 10-90%
Change over Time: Approximately 1s

Battery Charge Time: 24 hours
Battery warranty: 2 years

Having correctly identified the wiring from your existing light fitting, pull the wire through the hole, undo the cable clamp, and 
connect to the quick-fit connection block inside the product in the following way:

normally be off and charging. In the event of a power 
failure, the light will switch on automatically.

     - Initial: 30s function test is automatically run 20 hours       

   after mains power supplied to fitting. 3hr duration test  
   is automatically run after a further 4 hours 

   - Monthly: 30s test - power failure simulation: -  

   Green power indicator blinks.  

  simulation: - Green power indicator flashes.  

 Green power indicator flashes.  

and the yellow light will flash.

these steps:-

1. Press the "Test" button for 1s. Green light will be off and 

Emergency mode will run for 1s. Test button is located 
on the PCB.

2. Press the test button for 3s. Green light will be blinking 

and Function Test run for 30s.

3. Press the test button for 5s. Green light will be flashing 

and run duration test.

4. Press the test button again for 5s to interrupt duration 

test.

times and the fitting will be reset.

Operation & Testing

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

detach the front panel. Keep screws safe for refitting 
later.

of and drill out the fixing holes. Take care to avoid 
damaging any concealed wiring and pipes. Attach the 
fitting to the wall. The correct fixings should be used, 
depending upon the surface to be mounted.

to prevent cable damage. If using outside, an outdoor 
rated grommet must be used.

detailed overleaf.

Installation

is now ready for use.

Commissioning

SWITCHED LIVE

INSERT CABLE

NEUTRAL