Thank you for purchasing this light fitting.
Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.
Please retain these instructions for future reference.

Warning

Specification

Installation

Layout

Existing fittings must be completely removed before installation of a new product. Before removing the existing 
fitting, carefully note the position of each set of wires.

Voltage: 

240V 50Hz a.c.

Lamp: 

50W GU10 Halogen

IP rating: 

54

This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons 
cannot  restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified 
electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the connections.
Always use the correct type and wattage bulb.  Never exceed the wattage stated.

When changing a bulb, always switch off at the mains and allow the old bulb to cool down before handling.  
Dispose of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. 

Check with your local authority or retailer for recycling advice.
This product is rated at IP54.
This  product is not suitable for location in or near a marine environment.
The entire unit gets hot whilst on for a period of time.
If the external flexible cable or cord of this lamp is damaged the lamp must be returned to the service agent for 

repair.

• 

Decide  on  the  position  of  the  luminaire.  Depending  on  the  location,  an  approved  outdoor  rated  plug  and 
socket may be required. Alternatively an approved outdoor rated external terminal block may be used.

• 

Avoid locating any cables in positions that would cause a hazard. Position cables and connector block away 
from areas where they may be at risk from being cut, trapped or damaged.

• 

Cables that are to be in walls and concealed underground must be protected using suitable conduit or plastic 
trunking.

• 

Ensure that the ground is suitable for pushing the spike into, and can support the luminaire. Do not install in 
very wet or boggy areas.

97mm

340mm