background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 

satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This light fitting is Class 1 and must be connected to 
an Earth circuit

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 

electrician.

Install in accordance with IEE Wiring regulations and 

current Building Regulations.

To prevent electrocution switch off at mains supply 

before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge. If you are in any doubt, 

please consult a qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of 
the connections.

This system contains non-replaceable parts and 

cannot be serviced. If damage occurs the part should 
be scrapped.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

These products are rated at IP44.

These products are not suitable for dimming.

These products are not suitable for location in or near 

a marine or sea environment.

The entire units get hot whilst on for a period of time.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

30W LED module - 2200lm

IP rating: 

44

Layout

Installation

Having correctly identified the wiring from your existing 
light fitting and connect to the connection block inside 

the product in the following way:

Wiring - 67176

Check that...

•  You have correctly identified the wires.
•  The connections are tight.

• 

No loose strands have been left out of the connection 
block.

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the junction box and the light fitting

•  Avoid locating any cables in positions that would  

cause a hazard. Position cables and junction boxes 
(not supplied) away from areas where they may be 
at risk from being cut, trapped or damaged

•  Cables in walls must be protected using suitable 

conduit or plastic trunking. 

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm²

•  These products have special protection against the 

ingress of moisture and are IP44 rated.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, 

carefully note the position of each set 

of wires

.

•  The shade on these products is hinged. To open it, 

unscrew the 7 screws around the edge of the shade 
and keep them safe for refitting later (Fig.1)

•  The fixing holes are located in the corners of the wall 

back and they need to be punched or drilled through. 

The recommended hole size is 4.5mm (Fig. 2).

•  Using the wall back as a template, mark and drill the 

fixing holes and fit supplied wall plugs (suitable for 
masonry only - for other surfaces use appropriate 

fixings).  Use a sharp object such as a screwdriver 

to pierce the rubber grommet in the wall back and 
feed the incoming mains supply cable through the 
grommet entry hole. Fix the wall back to the wall 
using the supplied fixings.

•  Wire as detailed below..

NEUTRA

L

EA

RTH (GREEN/YELL

OW)  

SWITCHED LIVE 

BL

UE (N

)

GREEN/YEL

LOW

BROWN (L

)

SUPPLY

LIGHT FITTIN

G

Fig. 2

Fig. 1

Reviews: