background image

www.saxbylighting.com

Instruction manual

95541

Hero CCT Microwave

Saxby Lighting. BH17 7BY

V1 16/01/2021

We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.

Care and Safety

Microwave Movement Sensor

The light will not come on

The lamp is always on

The lamp will not work 
despite movement

Check detection area  setting

The lamp is on without any 
identifiable movement

Incorrect light-control setting selected

Continuous movement in the detection zone 

The sensor is not mounted for reliably detecting movement

Movement occurred, but not identified by the 
sensor (Movement behind wall, movement of 
small object in immediate lamp vicinity etc.)

Rapid movements are being suppressed to minimize
malfunctioning or the detection radius is too small.   

Faulty lamp
No power supply

Adjust daylight threshold setting
Replace lamp
Check power to sensor
Check detection area setting

Securely mount enclosure

1. Reduce sensitivity.
2. Check the movement behind walls to avoid 
    facilities such as water pipe, fan, which
    may mis-trigger the sensor.   

Trouble shooting:

Malfunction Cause Remedy

Cause

Remedy

This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.

Settings:

1 2 3

100%

75%
50%
25%
10%

1. Sensitivity

Sensitivity can be adjusted by selecting the
combination on the DIP switches for different
applications. 

  I –100%
 II –  75%

III –  50%

IV –  25%

2. Hold-time

Hold-time refers to the time period that the light
remains 100% on if no more movement is
detected.  

I – 5s
II – 30s
III – 90s
IV – 3min

3. Daylight sensor

Different daylight threshold can be preset on DIP
switches. Light will always turn on upon movement if
daylight sensor is disabled. 

7 8 9

2Lux

10Lux
25Lux
50Lux

Disable*

4 5 6

5s

30s
90s

3min

20min
30min

I –    2Lux
II –   10Lux
III –  25Lux
IV –  50Lux

 V  –  Disable

*Disable means the daylight sensor does not work. The sensor will turn
  on light once motion is detected regardless of ambient light level.

 V –  10%

V – 20min
VI – 30min

*

50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25% 

  sensitivity is not able to detect mo

tion signal.

Technical Specifications:

Operating voltage 

 

220 ~ 240V AC  50/60Hz

Rated load 

 

 

400W (Capacitive load)   800W (Resistive load)

Stand-by power 

 

0.5W

Sensitivity    

Hold-time 

 

 

5s / 30s / 90s / 3min / 20min / 30min

Daylight sensor  

 

2Lux / 10Lux / 25Lux / 50Lux / Disable

Microwave frequency   

5.8 GHz ±75MHz

Transmitting power 

 

1mW Max.

12-15m

 

3- 6m (radius )

 

Detection angle 

 

360

(Ceiling) / 120

(Wall)  

 

Working temperature   

-20

0

C ~ 60

0

C

100% / 75% / 50% / 25% / 10%

Ceiling mounted

height: 3m

Ceiling mounted

height: 3m
Wall mounted

height: 1.5-2m

Ceiling mounted

height: 6m 

Wall mounted

height: 2m

100% / 75% / 50%
100% / 75% / 50% / 25% / 10%

*

Detection range