www.saxbylighting.com
Instruction manual
95541
Hero CCT Microwave
Saxby Lighting. BH17 7BY
V1 16/01/2021
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
Care and Safety
Microwave Movement Sensor
The light will not come on
The lamp is always on
The lamp will not work
despite movement
Check detection area setting
The lamp is on without any
identifiable movement
Incorrect light-control setting selected
Continuous movement in the detection zone
The sensor is not mounted for reliably detecting movement
Movement occurred, but not identified by the
sensor (Movement behind wall, movement of
small object in immediate lamp vicinity etc.)
Rapid movements are being suppressed to minimize
malfunctioning or the detection radius is too small.
Faulty lamp
No power supply
Adjust daylight threshold setting
Replace lamp
Check power to sensor
Check detection area setting
Securely mount enclosure
1. Reduce sensitivity.
2. Check the movement behind walls to avoid
facilities such as water pipe, fan, which
may mis-trigger the sensor.
Trouble shooting:
Malfunction Cause Remedy
Cause
Remedy
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.
Settings:
1 2 3
100%
75%
50%
25%
10%
1. Sensitivity
Sensitivity can be adjusted by selecting the
combination on the DIP switches for different
applications.
I –100%
II – 75%
III – 50%
IV – 25%
2. Hold-time
Hold-time refers to the time period that the light
remains 100% on if no more movement is
detected.
I – 5s
II – 30s
III – 90s
IV – 3min
3. Daylight sensor
Different daylight threshold can be preset on DIP
switches. Light will always turn on upon movement if
daylight sensor is disabled.
7 8 9
2Lux
10Lux
25Lux
50Lux
Disable*
4 5 6
5s
30s
90s
3min
20min
30min
I – 2Lux
II – 10Lux
III – 25Lux
IV – 50Lux
V – Disable
*Disable means the daylight sensor does not work. The sensor will turn
on light once motion is detected regardless of ambient light level.
V – 10%
V – 20min
VI – 30min
*
50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25%
sensitivity is not able to detect mo
tion signal.
Technical Specifications:
Operating voltage
220 ~ 240V AC 50/60Hz
Rated load
400W (Capacitive load) 800W (Resistive load)
Stand-by power
≤
0.5W
Sensitivity
Hold-time
5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor
2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency
5.8 GHz ±75MHz
Transmitting power
1mW Max.
12-15m
3- 6m (radius )
Detection angle
360
0
(Ceiling) / 120
0
(Wall)
Working temperature
-20
0
C ~ 60
0
C
100% / 75% / 50% / 25% / 10%
Ceiling mounted
height: 3m
Ceiling mounted
height: 3m
Wall mounted
height: 1.5-2m
Ceiling mounted
height: 6m
Wall mounted
height: 2m
100% / 75% / 50%
100% / 75% / 50% / 25% / 10%
*
Detection range