Saxby Lighting Halbury Wall Instruction Leaflet Download Page 3

•  Refit the shade. Reconnect PIR sensor cable if necessary. 
•  Replace fuse or circuit breaker and switch on. Your light 

is now ready for use.

Commissioning

PIR Adjustment

•  When changing a bulb, always switch off at the mains 

and allow the bulb to cool before handling.

• Always use the correct type and wattage bulb. Using the 

incorrect wattage bulb will damage the bulb and ballast.

• Used bulbs should not be disposed of with household 

waste. Please recycle where facilities exist.

• Unscrew the bulb anticlockwise to remove.

• Insert the bulb gently into the fitting. Screw clockwise into 

the lampholder.

Fitting/replacing bulbs

Live Voltages may be present in this unit even when turned off or when completely disconnected.

 For your safety, 

always switch off the supply before changing lightbulbs, or cleaning.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. 
Check with your Local Authority or retailer for recycling advice.

Recycling advice

Safety information

We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could 
damage the finish.

1.  The unit must be installed in a vertical position, and fitted 

1.8m - 2.5m above the ground.

2. The PIR sensor can be adjusted using the LUX and TIME 

screws, allowing the detection distance to be altered 
to suit the location. The detection angle is set at 130 
degrees and the maximum detection distance is 12m. 
The PIR will start activating when the light level drops 

to  5  LUX  and  will  continue  to  activate  until  the  light 
level rises to 2000 LUX. When adjusting the sensitivity 

(detection distance) in daylight it will be necessary to 
cover the sensor to simulate night time. When the PIR 
is activated the light will remain lit for  a maximum of 5 
minutes. The minimum is 5 seconds.

40W E27 GLS

This light source is protected by a shade. This part must be replaced immediately should the shade 
become cracked or damaged. This fitting must not be used without the shade in place.

Reviews: