Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This product is Class 2 (Double insulated)
and must not be earthed.
Please read these instructions carefully before
commencing any work.
This unit should be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a
qualified electrician.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of the
connections.
This product contains non-replaceable parts and cannot
be serviced. If damage occurs the part should be
scrapped.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP44.
The diffuser (cover) can become hot in use. Switch off
and allow 10 minutes to cool before cleaning, replacing
or adjusting.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
60W E27 GLS
IP rating:
44
Layout
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting.
• Avoid locating any cables in positions that would cause
a hazard. Position cables and outdoor rated junction
boxes (not supplied) away from areas where they may
be at risk from being cut, trapped or damaged.
• We recommend that you use H05RN-F specification
cable (not supplied) which is an outdoor grade, rubber
sheathed cable. The mains supply cable must have a
minimum cross sectional area of 1.0mm²
• Cables must be protected using suitable conduit or
plastic trunking.
Existing fittings must be completely removed before
installation of a new product.
Before removing the
existing fitting, carefully note the position of each set
of wires
.
• The help of an assistant is recommended when
installing this fitting.
• Remove 6 securing screws to separate shade from wall
back. PIR sensor connection cable can be disconnected
to make installation easier(see Fig. 1).
• Using the wall back as a template, mark the position
of the mounting holes. Drill holes and fit supplied wall
plugs (suitable for masonry only - for other surfaces use
appropriate fixings). Feed the incoming mains supply
cable through the grommet entry hole. Fix the wall back
to the wall using the supplied screws (See Fig. 2).
• Wire as detailed below.
Installation
Fig. 2
Fig. 1
Wiring
This product is double insulated and must not be earthed.
If there are any incoming earth cables, they must be joined
together and well insulated with good quality insulation tape.
This is to ensure earth continuity throughout your property.
Remove the cover from the mains terminals and having
correctly identified the wiring from your existing light
fitting,connect to the quick fit connection block in the
following way:
ive
eutra l