background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This product is Class 2 (Double insulated) 
and must not be earthed.

Please read these instructions carefully before 
commencing any work.

This unit should be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without 
your knowledge. If you are in any doubt, please consult a 
qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of the 
connections.

This product contains non-replaceable parts and cannot 
be serviced. If damage occurs the part should be 
scrapped.

Waste electrical products should not be disposed of with 
household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling 
advice.

This product is rated at IP44.

The diffuser (cover) can become hot in use. Switch off 
and allow 10 minutes to cool before cleaning, replacing 
or adjusting.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

60W E27 GLS

IP rating: 

44

Layout

•  Plan the desired layout of this fitting carefully, ensuring 

the cables will reach the distance between the junction 
box and the light fitting.

•  Avoid locating any cables in positions that would cause 

a hazard. Position cables and outdoor rated junction 
boxes (not supplied) away from areas where they may 
be at risk from being cut, trapped or damaged.

•  We recommend that you use H05RN-F specification 

cable (not supplied) which is an outdoor grade, rubber 
sheathed cable. The mains supply cable must have a 
minimum cross sectional area of 1.0mm²

•  Cables must be protected using suitable conduit or 

plastic trunking.

Existing fittings must be completely removed before 
installation of a new product. 

Before removing the 

existing fitting, carefully note the position of each set 
of wires

.

•  The help of an assistant is recommended when 

installing this fitting.

•  Remove 6 securing screws to separate shade from wall 

back. PIR sensor connection cable can be disconnected 

to make installation easier(see Fig. 1). 

•  Using the wall back as a template, mark the position 

of the mounting holes. Drill holes and fit supplied wall 
plugs (suitable for masonry only - for other surfaces use 

appropriate fixings). Feed the incoming mains supply 
cable through the grommet entry hole. Fix the wall back 
to the wall using the supplied screws (See Fig. 2).

•  Wire as detailed below. 

Installation

Fig.  2

Fig. 1

Wiring

This product is double insulated and must not be earthed. 
If there are any incoming earth cables, they must be joined 
together and well insulated with good quality insulation tape. 
This is to ensure earth continuity throughout your property. 

Remove the cover from the mains terminals and having 
correctly identified the wiring from your existing light 
fitting,connect to the quick fit connection block in the 
following way:

ive

eutra l

Reviews: