background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.

Please read these instructions carefully before 
commencing any work.

This fitting must be fitted to a suitable track that has 
been properly installed.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot restore the electrical supply 
without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

This light fitting should be connected to a fused circuit.

Always ensure that you always use the correct 
wattage lamp to match the control gear. Use of 
incorrect lamp will damage the lamp and the control 

gear. Do not operate with a failed bulb or without a 
bulb as this may damage the unit.

When changing a bulb, always switch off at the mains 
and allow the old bulb to cool down before handling. 

As with all metal halide fixtures, the unit must be 
allowed to cool down after switching off before the 
lamp is able to re-ignite.

Dispose of used bulbs carefully and responsibly.

This product is not suitable for dimming.

This product must not be connected to a PIR 
movment sensor.

This product is rated at IP65.

This  product is not suitable for location in or near a 
marine environment.

The entire unit gets hot whilst on for a period of time.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

PRS250 

250W E40 SONT or 250W E40 HQIT

 

PRS400 

400W E40 SONT or 400W E40 HQIT

IP rating: 

65

Layout

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the junction box and the light fitting.

•  Avoid locating any cables in positions that would 

cause a hazard. Position cables and outdoor rated 
junction boxes (not supplied) away from areas 
where they may be at risk from being cut, trapped or 
damaged.

•  We recommend that you use H05RN-F specification 

cable (not supplied) which is an outdoor grade, 
rubber sheathed cable. The mains supply cable must 
have a minimum cross sectional area of 1.0mm²

•  Cables must be protected using suitable conduit or 

plastic trunking.

•  Fitting must be positioned 350mm (A) away from 

surfaces above the fitting.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, carefully note the position of each set 
of wires
.

•  Decide on the most appropriate position based on 

the layout instructions given above.

•  We recommend that the bracket is removed from the 

product to assist the fitting of the product. Make a 
note of the postion of the washers.

•  Hold the product or bracket in place and mark the 

position of the holes. Ensure that the product is 
level.

•  Ensure the wall is capable of holding the weight 

of the product. Take care to avoid damaging 
any concealed wiring and pipes. The correct 
fixings should be used for brick, cavity walls or 
plasterboard. Fix the product to the wall.

•  Using fixings appropriate to the weight of the fitting 

and the mounting surface, secure the fitting in 
position.

•  Undo the screws holding the wiring cover in place 

and set aside.

Installation

Wiring

Check that...

•  You have correctly identified the wires
•  The connections are tight

•  No loose strands have been left out of the connection 

block.

NEUTRAL

EARTH (GREEN/YELLOW)  

SWITCHED LIVE 

BLUE (N)

GREEN/YELLOW

BROWN (L)

SUPPLY

LIGHT FITTING

Having correctly identified the wiring from your existing 
light fitting, connect to the connection block inside the 

product in the following way:

A

B