background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 

satisfactory operation of this product. Please retain these instructions for future reference.

Warning

Technical data

Please read these instructions carefully before 

commencing any work.

This light fitting should be connected to a circuit 

with a 30mA RCD fitted.

We recommend that you use H05RN-F 

specification cable (not supplied) which is an 

outdoor grade, rubber sheathed cable. 

The mains supply cable must have a minimum 

cross sectional area of 1.0mm²

The products can be wall or ceiling mounted. If 

wall mounting ensure that the power supply is 

at the bottom.

This unit must be fitted by a competent and 

qualified electrician.

Check the pack and make sure you have all of the 

parts listed. 
To prevent electrocution switch off at mains supply

before installing or maintaining this fitting.

Ensure other persons cannot restore the electrical

supply without your knowledge.

Install in accordance with IEE Wiring regulations

 and current Building Regulations.

Supply 

Bulb Type:

Voltage: 

240V~, 50 Hz

LED (16W)  SMD 2835 3000K 

The light source of this luminaire is not replaceable; when the light source reaches its end 

of life the whole luminaire shall be replaced.

Conformity with all relevant EC Directive requirements.

Waste electrical products should not be disposed of with household waste.

Please recycle where facilities exist.Check with your Local Authority or

local store for recycling advice.

This product is not suitable for dimming.

Class I product, must be connected to earth.

Splash-proof

Installation

Commissioning

Existing fittings must be completely removed before installation of a new product. Before removing the 

existing fitting, carefully note the position of each set of wires.       

Note that the switch is turned off before installation.

Ensure that the screws and cable entry points 

are sealed to maintain the IP rating of the product.

Refit the shade, ensuring that the seals are 

correctly located.

Rotate and remove the shade.

Hold the product in place and mark the position of the holes. 

Ensure the wall is capable of holding the weight of the 

product, or if fitting to a ceiling, ensure there is a joist 

at the point of fixing to support the weight of the product.

Fix the base to the wall using the screws and plugs. 

Take care to avoid damaging any concealed wiring 

and pipes.  The correct fixings should be used for 

brick, cavity walls or plasterboard.

Pierce a hole in the grommet, and pull the cable through.

IP44

or plastic trunking.

Cables must be protected using suitable conduit 

If replacing an existing fitting, make a careful note 

of the connections.

Layout

Plan the desired layout of these fittings carefully,  ensuring the cables will reach the distances 

each light fitting. 

Avoid locating any cables in positions that would 

cause a hazard. Position cables and junction 

boxes (not supplied) away from areas where 

they may be at risk from being cut, 

trapped or damaged.
If this unit is being fitted in a room containing 

a bath or shower, a 30mA RCD must be 

used - in accordance with IEE regulations.

This product is suitable for use in living areas, 

Bathroom Zone 2 and outsides of zones.

225cm

60cm

240cm

60cm 

radius

from tap

ZONE 1

ZONE 0

ZONE 2

ZONE 2

Bathroom Zones Diagram

Gently push your chosen casing onto 

the  shade until it clips in place.

Replace fuse or circuit breaker and 

switch on. Your light is now ready for use.

Reviews: