Specification
Voltage:
240V 50Hz
Lamp:
46393: 20W COB LED 51902: 30W LED (COB)
IP rating:
20
Layout
• Plan the desired layout of these fittings carefully,
ensuring the cables will reach the distances between
the LED Driver and each light fitting.
• Ensure that there is adequate ventilation for the LED
Driver.
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• The distance between units must be 0.5m minimum.
• The unit must be located 0.2m away from a joist.
• This product must be mounted out of arms reach.
• This product is not suitable for bathrooms.
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting,
carefully note the position of each set
of wires
.
• Position the LED Driver next to the mains supply that
the system will connect to. Do not connect at this
stage.
• Cut a 165mm diameter hole for 43693 using an
appropriate tool. The cut out size for 51902 is
205mm.
• Ensure that the void depth is a minimum of 200mm.
• It is recommended to cut the hole slightly smaller
than needed, then file the hole until the recessed unit
fits snugly.
• Ensure free movement of air by removing void
insulation from at least 150mm from around the
hole. Under no circumstances must these fittings
and drivers be covered with insulating matting or
similar material.
Installation
Wiring
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
Having correctly identified the wiring from your existing
light fitting, pull the wire through the hole and connect to
the block in the following way:
This unit is double insulated and must not be earthed. If
there are any incoming earth cables, they must be joined
together and well insulated with good quality insulation
tape. This is to ensure earth continuity throughout your
property.
This product is Double Insulated and does
not require connection to an Earth circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
This system operates at Safety Extra Low Voltage, via
the supplied LED driver. Never connect the light fittings
directly to the mains without using the supplied LED
driver.
Always disconnect the LED driver from the mains
when installing or maintaining this system.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
This fitting must always be fitted to a plasterboard
ceiling. This must not be fitted to a plaster and lath
ceiling
This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
be scrapped.
This product is not suitable for dimming.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.