6. Tighten the lock nuts (D).
7. Confirm the bevel indicator is pointing to 0. In this
example, the indicator is not pointing to 0.
8. Loosen the screw for the indicator.
9. Shift the indicator to align with 0° on the bevel scale.
10. Tighten the screw for the indicator.
How to Calibrate the Miter
Gauge
Confirm that the miter head, or scale, and pointer are
correctly aligned with the guide rail of the miter
gauge. In the following example, the pointer (A) has
been knocked out of alignment, which means that the
values on the scale will be incorrect, as referenced to
the pointer; in this case, the scale is set to 90° (B) but
the real angle is 89.18° (C) or 90.82° (D).
Tools needed:
•
Phillips screwdriver
•
Combination square
1. Loosen the locking knob.
2. Loosen the screw for the pointer.
D
D
B
C
D
A
!
!
SawStop
®
Compact Table Saw
|
45