9
ENGLISH
Heater Installation
The heater can be placed wherever in the sauna, but for safety and convenience, follow the
minimum safety distances as provided in Fig. 2. Follow the cubic volumes given in the Technical
Diagram (page 16.). Do not install the heater to the floor or wall niche. Do not install more than
one heater in a sauna room unless you follow the special instructions for twin-heater installations.
In most countries, there is a law that requires heaters to be screwed to the floor as provided in
Fig. 1a. Install bracket support for safety purposes Fig. 1b.
The heater gets very hot. To avoid the risk of accidental contact with the heater, it is
recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A certified electrician
must do the installation of the heater to ensure safety and reliability. Improper electrical connection
can cause electric shock or fire. Refer to the electrical diagram in page 8.
OBS!
Se styrenhetens bruksanvisning för
maximal märkeffekt. En
kontaktorenhet behövs om
aggregatets märkeffekt överskrider
den separata styrenhetens kapacitet.
En ytterligare kontaktorenhet kan
anslutas till aggregat med 10,5 kW
och högre effekt.
NOTE:
Please refer to the control unit
manual for maximum power rating.
Contactor unit is needed if heater’s
power rating exceeds separate
control unit’s capacity. Additional
contactor unit can be connected to
the heaters 10,5kW and higher.
Min. säkerhetsavstånd (mm)
Minimum Safety Distances (mm)
Bild 2
Fig. 2
A
B
20
m
a
x
. 5
0
0