17
5.
4. Insert the temperature sensor through the
steam room wall. Do not apply staples or
other material that may damage the cable.
Apply silicone sealant on the hole in the wall
to create a moisture seal (Fig. 4). Make sure
that there is no trace of silicone on the
sensor as it may interfere its reading.
Fig. 4
Fig. 5
Silicone Sealant
Cable
Wall
Fig. 3
Push sensor
head to lock
Push to the
wall to stick
Installing the Temperature Sensor
(for illustrative purpose only)
Figure 1
The temperature sensor comes along with the SAWO steam generator. It is recom-
mended to use only Sawo temperature sensor with Sawo generator as it may other-
wise not function correctly.Temperature sensor wiring should not be routed near
power cables or hot areas as it may cause electronic interference or damage to the
wires.
An 25mm hole is required to insert the temperature
sensor. Do not create bigger or smaller hole. Clean
the hole before inserting the sensor.
Make a hole in the cable lead-in on the side of
the generator to pull the cable through. Connect
the cable in the terminal block marked as
"TEMP". See figure 2.
The temperature sensor has to be installed:
1.
2.
3.
TEMP
Terminal Block
Figure 2
SAWO Steam Generator
(shown with cover removed)
Temperature
Sensor
Before installation main supply of the generator must be switch off from the
circuit braker.
Height 1.2-1.5 meters above the floor away from the steam
head so that the steam will not hit the sensor directly.
The sensor has an integrated 9-meter cable. If longer cable is
needed use 2 x 0.5 mm2 to 2 x 1.0mm2 cable for extension.