SAFETY INSTRUCTIONS

Please take note of these safety precautions before using the sauna or when installing 

the heater.

For user: 

• 

This product is not designed to be used by persons (including children) 

with limited physical or mental abilities and limited experience and  

knowledge except under close supervision by a responsible person 

with knowledge and experience or having been advised by such person. 

• 

Cleaning and user maintenance shall not be made by children without  

supervision.

• 

Under no circumstances should children be allowed to play with the device. 

• 

Do not use the heater as a grill.

• 

Do not put wood of any kind on the electric heater.

• 

Do not cover the heater. It may cause a fire.

• 

Do not use the heater as clothes dryer. It may cause fire.

• 

Never sit on the heater. It is really hot and can cause serious burns.

• 

Do not use chlorinated water (e.g. From the swimming pool or  

jacuzzi) or seawater. It can destroy the heater.

• 

When installing a new heater, switch the heater on for 30mins. Do not stay 

inside the sauna room while performing the operation. (See page 25)

• 

Make sure that no flammable objects have been placed on the heater before 

activating the preset time function or the stand-by mode for the remote 

operation.

Summary of Contents for ROUND TH12-150NS

Page 1: ...una heater Please read the manual carefully before using the heater Onnittelut loistavasta kiuasvalinnasta Tutustu huolellisesti k ytt ohjeisiin ennen tuotteen k ytt TH2 30NB TH3 35NB TH3 45NB TH3 60N...

Page 2: ...ajalle 6 Kiukaan Asennus 8 Kiuaskivet 10 Kivien Ladonta Kiukaaseen 10 Huohotin 12 Kiukaan k ytt ilman huohotinta NB mallit 13 Ohjauss timet NB mallit 14 Termostaatti 14 Ajastin 14 Kytkent kaavio 15 Se...

Page 3: ...Insulation 23 Heating of the sauna room 25 Sauna maintenance 27 Diagnostic table 29 Technical data 30 Quality requirements for water which is thrown to the heater 31 Tower heater spare parts 31 NOTE...

Page 4: ...huoltaa kiuasta ilman valvontaa l anna koskaan lasten leikki kiukaalla l valmista ruokaa kiukaalla l laita puita s hk kiukaalle l peit kiuasta Se aiheuttaa palovaaran l kuivata vaatteita kiukaalla Se...

Page 5: ...ces should children be allowed to play with the device Do not use the heater as a grill Do not put wood of any kind on the electric heater Do not cover the heater It may cause a fire Do not use the he...

Page 6: ...intaan Ohjauspaneeli voidaan asentaa valintasi mukaan saunan ulko tai sis puolelle Julkisessa k yt ss olevaan kiukaaseen jossa on viikkoajastin tai kauko ohjaus mahdollisuus on asennettava erillinen o...

Page 7: ...control panel must be mounted outside the sauna cabin If this sauna heater is used for public saunas or saunas that may be switched on by a separate remote control system the door of the sauna room m...

Page 8: ...uuksia Katso sivu 30 tekniset tiedot tulee noudattaa Saunaan saa asentaa vain yhden kiukaan ellei sinulla ole erikoisohjeita kahden kiukaan asentamiseen Useimmissa maissa kiukaan kiinnitt minen lattia...

Page 9: ...nstall the heater to the floor or wall niche Do not install more than one heater in a sauna room unless you follow the special instructions for twin heater installations In most countries there is a l...

Page 10: ...lloinkaan ty nt v kisin l mmityselementtien v liin vaan t llaiset kivet on poistettava Varmista ett l mmityselementtej tukeva teline on tukevasti paikallaa Kivet ovat ladottava siten ett elementit eiv...

Page 11: ...or during the first few times of using the heater It is important that the stones are loaded carefully in a way that they do not block air circulation through the heater Load the stones to the heater...

Page 12: ...kosteammat l ylyt STONE SPACER The heater can be used with or without the stone spacer depending on the preference of the user See comparison below WITH STONE SPACER Faster heating ability thus saves...

Page 13: ...oripidikkeen p lle samaan tapaan kuin se oli ennen sen irrottamista Huohottimen k ytt minen ilman l mm n johdinta voi aiheuttaa palovaaran WHEN NOT USING STONE SPACER FOR NB ONLY 1 Remove Stone Spacer...

Page 14: ...l start and remain on for the time selected To preset the timer simply turn the knob to anywhere between 1 8 When the specific number of hours is reached the heater will start running and stay on for...

Page 15: ...G 2 0 1 5 2 0 1 5 2 0 N U V W G 1 5 1 5 1 5 1 5 2 0 TH3 35NS 3 5 kW 380 415V 3N 50 60Hz 220 240V 3 50 60Hz 220 240V 1N 50 60Hz W V U N N G W V U N N W V U U V W N N G U W V N H1 H2 H3 W V U N N G 220...

Page 16: ...U W V U N G N G 2 0 1 5 2 0 1 5 2 0 1 5 TH6 105NS 6 0 kw 4 5 kw T1 T2 W V U W V U W V U W V U TH6 120NS 6 0 kw 6 0 kw T1 T2 W V U W V U W V U W V U N G N G 2 0 2 0 2 0 2 0 2 0 2 0 N G N G 1 5 1 5 1 1...

Page 17: ...5 1 15 1 5 15 0 kW TH9 180NS N G N G 6 0 kw 12 0 kw 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 T1 T2 W V U W V U 18 0 kW N G N G 1 5 2 0 1 5 1 5 2 0 1 5 1 5 2 0 1 5 TH9 150NS 15 0 kW 9 0 kw 6 0 kw T1 T2 W V...

Page 18: ...B1 L2 N L1 N K 230V PREMIUM ONLY SENSOR 230V of N K is an output voltage for control of heating in the household and not for input supply Usage is optional 3 PHASE 1 PHASE L1L2L3 380 415V 3N 50 60Hz N...

Page 19: ...ly Usage is optional 230V of N K is an output voltage for control of heating in the household and not for input supply Usage is optional 230V of N K is an output voltage for control of heating in the...

Page 20: ...ng a separate control with the heater the temperature sensor with safety fuse which prevents the heater from overheating must always be installed in the ceiling directly above the center of the heater...

Page 21: ...ation or inappropri ate ventilation Exposure of the sensor to the glow ing heating element may cause sensor to overheat If this occurs find out the cause and fix the problem before resetting the safet...

Page 22: ...et seiniss katossa ja ovessa Mik li saunassa on yksi neli metri m erist m t nt sein pintaa esim lasiovi tiili tai kaakelisein on saunan tilavuuteen laskettava suunnilleen 1 2 kuutiometri m lis Katso s...

Page 23: ...through a pipe from the floor going to a vent to the sauna ceiling or under the door to the washroom In this case the sill slot must be at least 5cm and it is recommended that there is mechanical vent...

Page 24: ...k yt n Mik li savua tai hajua muodostuu yh poistu saunasta v litt m sti ja toista vaiheet 1 3 uudelleen Tarkistasaunaainaennenkiukaanp llekytkemist etteikiukaallataisensuojaet isyyksien sis ll ole mit...

Page 25: ...for the first time 4 If no smoke or odor is produced the next time the sauna heater is heated up you can start to use the sauna If smoke or odor is produced again leave the sauna cabin immediately and...

Page 26: ...uteet lattia katto ja sein t l k yt puupintojen pesuun ammoniakkia tai klooria sis lt v pesuainetta Huuhtele pesuaine pois kylm ll vedell Tuuleta sauna hyvin Halutessasi voit k sitell lauteet saunapin...

Page 27: ...h Wash sauna benches ceiling floor and walls Do not use detergent which includes ammonia or chlorine Rinse surfaces with cold water and ventilate sauna room well If needed protect wood surfaces with w...

Page 28: ...2 NI JA NS MALLIT Onko kiuas laitettu p lle ohjauskeskuksesta Onko tavoitel mp tila s detty saunan l mp tilaa korkeammaksi Onko kiukaan p kytkin p ll Ni malleissa kytkin sijaitsee kiukaan alaosassa ja...

Page 29: ...Is the set temperature higher than the temperature inside the sauna room Is the main switch ON In Ni models main switch is located at the bottom of the heater and in NS models it is on the power cont...

Page 30: ...300 1300 1300 1300 1300 1300 1300 1300 1300 4 x 1 5 3 x 2 5 5 x 1 5 5 x 1 5 5 x 1 5 4 x 1 5 3 x 2 5 5 x 1 5 5 x 1 5 5 x 1 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x 2 5 5 x...

Page 31: ...eposits Health risk Fast corrosion 12 mg l 0 2 mg l Mn 0 05 mg l Ca 100 mg l Not allowed to use Not allowed to use L YLYVEDEN LAATUVAATIMUKSET QUALITY REQUIREMENTS FOR WATER WHICH IS THROWN TO THE HEA...

Page 32: ...ERMOSTAT TIMER HP41 002 HP41 003 HP41 004 HP41 007 HP41 028 HP41 029 HP01 014 HP01 010 HP01 011 HP31 006 HP01 022 B1 HP01 022 HP01 066 HP01 065 HP03 004 HP41 009 HP41 031 HP41 026 3 H E HP42 002 4 5 H...

Reviews: