HEATER INSTALLATION
The heater can be placed wherever in the sauna, but for safety and convenience, follow
the minimum safety distances as provided below (See page 9). Follow the cubic
volumes given in the Technical Data (See page 30). Do not install the heater to the
floor or wall niche. Do not install more than one heater in a sauna room unless you follow
the special instructions for twin-heater installations. In most countries, there is a law that
requires heaters to be screwed to the floor.
The heater gets very hot. To avoid the risk of accidental contact with the heater, it is
recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A certified
electrician must do the installation of the heater to ensure safety and reliability. Improper
electrical connection can cause electric shock or fire. Refer to the electrical diagram (See
NOTE!
Remove the carton from the heating
elements before installing the heater
as it is only intended to protect them
during shipment.
Minimum safety distances (mm)
Minimisuojaetäisyydet (mm)
HUOM!
Poista suojapahvi vastuksista ennen
kiukaan asentamista. Pahvi on
tarkoitettu ainoastaan suojaamaan
vastuksia kuljetuksen aikana.