Sawo 21 Installation And Manual Download Page 2

INSTRUCTIONS FOR 

SAWO

 SAUNA HEATER’S

INSTALLATION, USAGE AND CARE

Congratulations on your good choice of a sauna heater! 

SAWO

 sauna heater is a high 

quality and traditional Finnish product, that will serve you longer if used and taken
care of properly. Read the instructions carefully before using the 
sauna heater as this manual describes the sauna heater installation, usage and care. 
Please keep the manual for later reference.

WARNING

TO BE NOTED

TECHNICAL INFORMATION 

rust!

Sauna minimum and

 a maximum volume

Table 1.

Height

8...21 m³

143 mm

702mm

T600

Ø100 mm

690 mm

430 mm

490 mm

35 cm

Width

Depth

Max length of fire wood

Optional exhaust outlet at 

the back(horizontal)

Required temperature 
class of chimney

Replacement air opening minimum size

   110 mm 

1

wood or removing residual material.

The heater hatch must be closed to prevent leaking of smoke, unless setting up fire, adding

Parts of the sauna heater, especially the outer case, are extremely hot to touch during 
usage.
Any changes to the sauna heater without authorization is forbidden.

Summary of Contents for 21

Page 1: ...Sauna Heater Installation and Manual ...

Page 2: ...eference WARNING TO BE NOTED TECHNICAL INFORMATION rust Sauna minimum and a maximum volume Table 1 Height 8 21 m 143 mm 702mm T600 Ø100 mm 690 mm 430 mm 490 mm 35 cm Width Depth Max length of fire wood Optional exhaust outlet at the back horizontal Required temperature class of chimney Replacement air opening minimum size 110 mm 1 wood or removing residual material The heater hatch must be closed ...

Page 3: ...nd 90 angled smoke pipe as for by 177mm higher Stone capacity Diameter of stones Weight Watercontainer volume Glassdoor Adjustable legs Included Optional Guiding plates of combustion air for cleaner burning 10 15 cm about35 kg 8 12 cm 56 kg Chimney type 30 l 2 ...

Page 4: ...the ventilation of the sauna room install the bare smoke pipe to the sauna heater for draught Before Installation SAWO Model SAWO 21 Wood è see table SAFETY DISTANCES NPD 464 C 16kW 0 36 62 12 Pa 5 3 7 kg 25 mm 17 6 g s Fuel Fire safety initiation to adjacent elements safety distances Emit of dangerous substances Temperature of smoke fuel in connecting fuel C when stove doors closed Heat output to...

Page 5: ...ributing plate By using adjustable legs optional it enables to adjust the sauna heater s position and lower part of the heater body to the brackets Adjust the heater to its position by un screwing the lower adjustable legs and lock it with the upper adjustable legs resistant SAWO heater is not suitable to be installed into a shared smoke duct system connection pipe see picture 1 Models which have ...

Page 6: ...ld the heater Always install the heater information If the heater pro tective shield ed 100 mm from both sides of the protected by using a heat shield made from metal sheet and is fixed underneath heater the heater in such a way that there is no openings or areas that the heat shields are not protecting properly the heater door 180 degrees and placing the kingpin to the other side of the cover hat...

Page 7: ...er vent close to the heater the sauna room Make sure that nothing can block the ventilation by placing a proper grill to the louver Combustion consumes lots of fresh air which makes gravity exhaust ventilation suitable for sauna rooms that uses wood for heating If you are plan to use mechanical exhaust ventilation the placement of the air inlet can also be above the heater If you place the air inl...

Page 8: ...heck that the grate is unbroken and on bracket smoke channels of the heater must be cleaned through the sweeping hole located on connecting opening cover is properly in place Sauna Water MAINTENANCE heating ash drawer can be open 25 mm up to restrictor If ash drawer is opened more when needed Heating Only natural wood must be used as a fuel for the heater Dimensions of the wood that Wood is the on...

Page 9: ...y distance dimensions Never cover the heater or outer cover air blowholes IN CASE OF SOOT FIRE ALSO IF IT HAS ALREADY BEEN EXTINGUISHED ALWAYS INFORM THE EMERGENCY CENTRE cover possible transport unloading or installation costs or other similar costs SAFETY INSTRUCTIONS WARRANTY 8 ...

Page 10: ... SAWO 21_ML FiEn 0715 Subject to change without notice ...

Reviews: