background image

 IH-61   11/2008 

Importer 

SAVO Design & Technic Oy 

 

www.savo.fi 

CONTROL PANEL 

Button A 

Light switch 

Button B 

Timer function on/off. 
By pressing the button, timer fuction activates and after 5 minutes motor turns off. 
Display 

C

 flashes the selected speed. 

Timer function remains on even if the speed is changed

Display C  

Displays selected motor speed. 
Displays the timer function (selected speed is flashing) 
Reminds of maintenance when central segment flashes. 

Button D 

Motor on (at the last selected speed) 
Pushing the button again, speed of the external motor is sequentially changing 
from 1 to 4. 
 
Turn off the motor keeping this button pressed for 2 seconds. 

Button R 

Grease filter alarm reset. 
When central segment flashes in display 

C

, grease filters must be cleaned. 

(30 hours) 
 
Reset the hours after cleaning by keeping this button pressed for 2 seconds. 

MAINTENANCE 

Cleaning the grease filter: 

(30 hours / 2 months)

 

Press the locking 

C

 and remove the grease filter. Wash by hand or in dishwasher. 

Use the first page instructions. 
 

Changing the halogen bulb: 

Open the cover gently pulling from the fissures. Make the replacement with 
similar bulbs (G4-20W). CAUTION: Do not handle glass bulb with bare hands. 

Winter start function: 
When turned on, motor works 
with speed 4 for a moment. 
Then the hood goes to the speed 
it was turned off at. 

Reviews: