4. CONTROLS

Key Function

LED

L

Turns the lights on/off at maximum intensity.

-

Pressing the key for approximately 2” activates/deactivates the 

Winter Start

 function 

(See the section described below). 

When 

Wintr Start

 is enabled, LED 

S1

  flashes  only  once,  while  if  Winter  Start  is 

disabled, LED 

S1

 flashes twice.

-

T1

Turns  the  motor  on/off  at  the  first  speed.

On / Off

T2

Turns the motor on at the second speed.

On / Off

T3

Turns the motor on at the third speed.

On / Off

T4

Short press: Turns the motor on/off at 

INTENSIVE

 speed. This speed is 

timed to 6 minutes. At the end of this time, the system automatically returns 

to the previously selected speed.

Flashing

Long press: The “

Speed1 tuning

” menu is entered. For details on the 

menu, see the dedicated section below.

-

5.  ENGINE SETTINGS

Disconnect the hood from the wall socket. Wait for around 5 seconds. Then reconnect the hood and immediately 

press the T4 button for at least 7 seconds. The hood now switches to motor setting mode, as indicated by the LED on 

button T2. If the light does not turn on, repeat the steps.

The operation of engine settings consists of two consecutive stages:

1] Engine type Note:(AC or EC)
2] Setting of engine control speeds

1. Selection of motor type (AC or EC)

The hood can only control one AC or more EC motors at a time. The AC motor is selected as factory setting. 

The T4 button selects the AC motor, as an indication of this, the LED light S1 turns on.

The T3 button selects the EC motor, as an indication of this, the LED light S1 turns off.

The choice of motor type is confirmed by pressing the T2 key. After that, the settings move to the setting of the 

engine control speeds.

Note! The EC motor always needs its own separate 230 VAC operating voltage. It is not possible to use the AC 
engine control outlet for this!

Summary of Contents for dCH-6506-S2

Page 1: ...K ytt ohjeet Anv ndningshandbok User Manual dIH 6509 S2 dCH 6506 S2 dCH 6509 S2...

Page 2: ...arten on tark istettava ett kodin s hk ver kossa on sopiva maadoitus Liit liesituuletin savuhormiin putkella jonka l pimitta on v hint n 120 mm Savun poi storeitin on oltava mahdollisim man lyhyt Kaik...

Page 3: ...lla hyvin kuumiksi keittolaitteidenk yt naikana Puhdista ja tai vaihda suodat timet m r tyn ajan kuluttua tulipalovaara Katsokappaletta Huolto ja puhdistus Tilassa t ytyy olla asianmuka inen tuuletus...

Page 4: ...umentunut ljy voi sytty palamaan 3 PUHDISTUS JA HUOLTO Rasvasuodattimet t ytyy puhdistaa aina 2 kuukauden k yt n j lkeen tai useammin jos laitetta k ytet n paljon Ne voidaan pest astianpe sukoneessa Z...

Page 5: ...ta liesikupu sein s hk st Odota v hint n noin 5 sekuntia Kytke sitten liesikupu takaisin s hk ihin ja paina heti v litt m sti T4 painiketta v hint n 7 sekunnin ajan Liesikupu siirtyy nyt moottorin ase...

Page 6: ...jausj nnitteet EC M B 1 VDC M B 2 VDC M B 3 VDC M B 4 VDC M B 5 VDC M B 6 VDC M B 7 VDC M B 8 VDC 1 NOPEUS 1 7 2 2 3 2 6 2 9 3 2 3 5 3 8 2 NOPEUS 3 5 3 8 4 1 4 4 4 7 5 5 3 5 6 3 NOPEUS 5 2 5 5 5 8 6 1...

Page 7: ...m n j lkeen S1 syttyy ja j palamaan p lle Led valo T4 vilkuttaa 5 kertaa Em vilkuttamissykli jatkuu niin kauan kunnes asetuksista poistutaan YKK SNOPEUDEN OHJAUSJ NNITTEEN MUUTTAMINEN TALLENTAMINEN JA...

Page 8: ...ra gningsbest mmelserna F r apparater i klass I s ker st llattbostadenselsystemhar en l mplig jordanslutning Anslutk ksfl ktentillimkanalen med ett r r med min diameter p 120mm Str ckand rmatos avleds...

Page 9: ...arn under uppsikt s att de inte leker med apparaten Denna apparat f r inte anv n dasavpersoner inkl barn med nedsatt fysisk sensorisk eller mental funktionsf rm ga eller personer som saknar erfaren he...

Page 10: ...rig uppkommer h ga l gor under k ksfl kten n r den r ig ng Justera l gans styrka s att den endast ber r kokk rlets botten och inte slickar utmed dess sidor Frit serna ska kontrolleras hela tiden under...

Page 11: ...MOTORINST LLNINGAR Koppla bort fl kten fr n v gguttaget V nta ungef r 5 sekunder Koppla sedan in fl kten igen och tryck omedelbart in T4 knappen i minst 7 sekunder Fl kten skiftar nu till motorinst l...

Page 12: ...M B 1 VDC M B 2 VDC M B 3 VDC M B 4 VDC M B 5 VDC M B 6 VDC M B 7 VDC M B 8 VDC 1 A HASTIGHET 1 7 2 2 3 2 6 2 9 3 2 3 5 3 8 2 A HASTIGHET 3 5 3 8 4 1 4 4 4 7 5 5 3 5 6 3 A HASTIGHET 5 2 5 5 5 8 6 1 6...

Page 13: ...ED lampan T4 blinkar 3 g nger D refter t nds S1 och f rblir t nd LED lampan T4 blinkar 5 g nger T EX den blinkande cykeln forts tter tills inst llningarna avslutas NDRA SPARA OCH AVSLUTA ENHASTIGHETS...

Page 14: ...arantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimumdiameter120mm The routeofthefluemustbeasshort as possible Regulations concerning the dis charge of air hav...

Page 15: ...r household waste disposal service or the shop where you purchased the product WARNING Before installing theHood removetheprotec tive films Useonlyscrewsandsmallparts in support of the hood WARNING Fa...

Page 16: ...djust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst...

Page 17: ...od from the wall socket Wait for around 5 seconds Then reconnect the hood and immediately press the T4 button for at least 7 seconds The hood now switches to motor setting mode as indicated by the LED...

Page 18: ...for memory banks EC M B 1 VDC M B 2 VDC M B 3 VDC M B 4 VDC M B 5 VDC M B 6 VDC M B 7 VDC M B 8 VDC 1 SPEED 1 7 2 2 3 2 6 2 9 3 2 3 5 3 8 2 SPEED 3 5 3 8 4 1 4 4 4 7 5 5 3 5 6 3 SPEED 5 2 5 5 5 8 6 1...

Page 19: ...rt of the voltage i e 3 The LED T4 flashes 3 times After this S1 lights up and remains lit The LED T4 flashes 5 times E G the flashing cycle continues until the settings are exited CHANGING SAVING AND...

Page 20: ...991 0659 645_06 220610 D000000008108_05...