EN
1
11
Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when led
S1
starts to flash, or at
least once every 4 months. The Alarm signal, if it has been activated, only appears when the
Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press button
T2
and hold it for
5 seconds
until the LED flashes twice in confirmation:
CHANGING
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press
T3
and hold for at least 3 seconds, until LED flashes
three times in confirmation.
Changing the Filter
• Open the lighting unit by pulling on the notch provided.
• Remove the Metal Grease Filter
• Remove the saturated Activated charcoal filter, using the hooks
provided.
• Fit the new Filter, hooking it into place.
• Fit the Grease filter and the Light Unit back into place.
Lighting unit
Warning:
This appliance is fitted with a white LED lamp classed
as 1M according to EN 60825-1: 1994 + A1:2002 + A2:2001
standards; maximum optical power emitted @439nm: 7µW. Do
not look directly at the light through optical devices (binoculars,
magnifying glasses…).
• For replacement contact technical support
("To purchase con-
tact technical support").
Summary of Contents for C-7804-S
Page 1: ...Instructions Manual Käyttöohje C 7804 S C 7804 W ...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ...991 0364 426_ver1 150209 ...