Warning

• 

Install proper safety guards as needed.

• 

Keep fingers and objects away from openings and rotating parts.

• 

When provided, motor terminal covers must be in place for safe operation.

• 

Product surfaces become very hot during operation, allow product surfaces to cool before 

handling

• 

Air stream from product may contain solid or liquid material that can result in eye or skin damage, 

wear proper eye protection.

• 

Wear hearing protection. Sound level from motor may exceed 70 dB(A).

• 

Do not start against a vacuum or pressure load.

• 

Failure to follow these instructions can result in burns, eye injury, or other serious injury.

Start Up

If motor fails to start or slows down significantly under load, shut off and disconnect from power 

supply. Check that the voltage is correct for motor and that motor is turning in the proper direction. 

Check the plug, cord and switch for damage. If so equipped, the thermal protection switch has 

tripped, the motor can restart after cooling.

Maintenance

Disconnect electrical power supply cord before performing maintenance on this product.

If product is hard wired into system, disconnect electrical power at the circuit breaker or fuse box, 

before performing maintenance on this product. 

Product surfaces become very hot during operation, allow product surfaces to cool before handling-

Air stream from product may contain solid or liquid material that can result in eye or skin damage, 

wear proper eye protection. Clean this product in a well-ventilated area.

It is your responsibility to:

• 

Regularly inspect and make necessary repairs to product in order to maintain proper operation.

• 

Make sure that pressure is released from product before starting maintenance.

Failure to follow these instructions can result in burns, eye injury, or other serious injury.

Check intake filter after first 500 hours of operation. Clean filter and determine how frequently filter 

should be checked during future operation to assure the product’s performance.

1. 

Disconnect electrical power supply to unit.

2. 

Vent all air lines.

3. 

Remove filter cover.

4. 

Check filter felt. Replace felt if it is covered with contamination or shows signs of increasing 

differential pressure.

5. 

Re-install felt and filter cover.

4

Operation

Summary of Contents for Savio2 SO2400

Page 1: ...Aeration primarily helps break up thermocline that can develop over time in a static pond In the Savio2 Aeration Systems air is forced through our rubber membrane weighted disc diffusers and circulat...

Page 2: ...on Criteria Pump only clean dry air Operate at 32 F 1O4 F O C 40 C Protect unit from dirt and moisture Do not pump flammable or explosive gases or use in an atmosphere that contains such gases Protect...

Page 3: ...t the outlet have the proper outlet installed by a qualified electrician The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinanc...

Page 4: ...ly cord before performing maintenance on this product If product is hard wired into system disconnect electrical power at the circuit breaker or fuse box before performing maintenance on this product...

Page 5: ..._________________________________ _________________________________________________________ _________________________________________________________ __________________________________________________...

Page 6: ...e for Models SO2400 SO2750 SOR031 Isolation Base for Models SO21100 Not Pictured Replacement Parts SOR005 Capacitor Case for Model SO2400 SOR006 Capacitor Case for Model SO2750 SOR007 Capacitor Case f...

Page 7: ...Air Silencer SOR012 Set of 4 Shock Absorbing Feet SOR015 3 Way Outlet Manifold SOR016 4 Way Outlet Manifold SOR017 Shut Off Valve Each SOR018 1 4 NPT x 3 8 Hose Barb Each SOR020 Pressure Relief Valve...

Page 8: ...use installation and handling of the device or as a result of wear and tear Savio Engineering does not assume liability for consequential damage caused by the failure of the product Removal of cord or...

Reviews: