3
Installation
Accessories
This product has an external intake and filtration. Check filter periodically and replace when
necessary. Consult your Distributors/Representative for additional filter recommendations.
Install relief valve(s) at inlet or outlet or both, to monitor performance. Check Valves may be required
to prevent back streaming through the pump.
Motor Control
It is your responsibility to contact a qualified electrician and assure that the electrical installation is
adequate and in conformance with all national and local codes and ordinances. The metal capacitor
must be grounded.
Determine the correct overload setting required to protect the motor. Select fuses, motor protective
switches or thermal protective switches to provide protection. Fuses act as short circuit protection
for the motor, not as protection against overload. Incoming line fuses must be able to withstand the
motor’s starting current. Motor starters with thermal magnetic overload or circuit breakers protect
motor from overload or reduced voltage conditions.
Electrical Connection
Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a
qualified electrician. The plug must be plugged into an outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to
either flat blade terminal. The wire with insulation that is green or green with yellow stripes is the
grounding wire.
Check the condition of the power supply wiring. Do not permanently connect this product to wiring
that is not in good condition or is inadequate for the requirements of this product.
Failure to follow these instructions can result in death, fire, or electrical shock.
Check with a qualified electrician or serviceman if the grounding instructions are not completely
understood, or if you are not sure whether the product is properly grounded. Do not modify the plug
provided. It will not fit the outlet, have the proper outlet installed by a qualified electrician.
Power Supply Cord
This product must be grounded. For either 120-volt
or 220/240-volt circuits connect power supply cord
grounding plug to a matching grounded outlet. Do not
use an adapter. (See diagram.)
In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape
wire for the electric current.