background image

Minumum and Maximum Cord Lengths Per Voltage Input

Voltages

 are determined by the measured Voltage level @ the 

Bus Bar where the Transformer and Cords are connected while on White 

MINI MEL/MINI BLANCO/

MELODY

/

BLANCO MIN/MAX VOLTAGE PER CORD LENGTH

CORD LENGTH

Min. Voltage

Max. Voltage

15 Feet

7.8Vac

12.0Vac

30 Feet

8.6Vac

12.2Vac

50 Feet

9.4Vac

12.4Vac

100 Feet

10.7Vac

13.2Vac

150 Feet

11.82V

13.8Vac

MEL-SOL & BLANCO PRO MIN/MAX VOLTAGE PER CORD LENGTH

CORD LENGTH

Min. Voltage

Max. Voltage

20 Feet

9.8Vac

12.0Vac

30 Feet

9.92Vac

12.2Vac

50 Feet

10.34Vac

12.56Vac

100 Feet

10.9Vac

13.5Vac

150 Feet

11.43Vac

14.1Vac

Next Step Products provides these guidelines as a reference for proper operation.  Failure to adhere 
specifications could result in improper operation or synchronization of lights.

ALL VOLTAGE READINGS ARE TAKEN WHILE LIGHTS ARE ALL SET TO WHITE

As these Charts address the Minimum - please remember that at no time should the MAXIMUM 

distance with or without J Box extend past 150 ft.

Summary of Contents for -MELODY P

Page 1: ...WARNING These underwater swimming pool lights MUST BE installed by a licensed or certified electrician or a qualified pool professional in accordance with the National Electric Code NEC or the Canadian Electric Code CEC CSA C22 1 All applicable local installation codes and ordinances must also be adhered to Improper installation will create an electrical hazard which could result in death or serio...

Page 2: ...HRIDGE PARK COURT SUITE 200 ORLANDO FLORIDA 32819 USA Tel 407 855 5630 Fax 407 210 8679 nextstepproduct com 4 MIN FROM WATER LEVEL TO TOP OF LENS 1 5 Pipe 1 min Pipe Sweeps ONLY No 90 degree bends 4 MIN FROM WATER LEVEL TO TOP OF LENS 12VAC Pool Transformer Allow 18 24 slack for Service Loop Conduit to 12VAC transformer Tighten NOTE Service Loop not applicable for Junction Box Installations 1 5 TH...

Page 3: ... 2 seconds and turn back on DO THIS TWICE All the lights should be in the SAVI BLUE color mode If they are all fixed on BLUE you have now synchronized your lights If not turn the lights off for more than 20 seconds Turn back on and proceed to Step 1 OPERATING THE LIGHT 7 To move to the next color mode Turn the lights off for 1 2 seconds and turn back on Repeat until desired color mode is found Exa...

Page 4: ...le responsibility to verify and assure that proper gauging of secondary wiring from the Transformer to the J Box are in compliance with your local State and National Electrical Codes JB T JUNCTION BOX BUS BAR PX100 PX300 MAX WATTAGE MAX WATTAGE 0 50ft 100ft cord 168W 12GA 12V JB T 100ft 50ft cord 126W 10GA 12V JB T 130ft 20ft cord 98W 8GA 12V JUNCTION BOX BUS BAR PX100 PX300 0 50ft 100ft cord 210W...

Page 5: ...oduct com NOTE Please use appropriate low voltage supply to pool lights ie if 12V is appropriate voltage DO NOT use 13V or 14V tap on transformer output if so equipped WARNING DO NOT run 120V and Low Voltage wires in the same conduit or enclosures ALL Savi LED Colored Lights including Savi Color LED Light Drivers are designed to work or synchronize with each other Please follow all installations f...

Page 6: ...s series Look below and see if any one fits into your pool environment Keep in mind that these lenses can be added on to any of our 2013 LED Lights even if they have already been installed HALF DOME This escutcheon adds over the existing lens to allow you to direct 1 2 the light in a direction you want Downwards to light a pools interior without light shining upwards Upwards to light a waterfeatur...

Page 7: ...8Vac MEL SOL BLANCO PRO MIN MAX VOLTAGE PER CORD LENGTH CORD LENGTH Min Voltage Max Voltage 20 Feet 9 8Vac 12 0Vac 30 Feet 9 92Vac 12 2Vac 50 Feet 10 34Vac 12 56Vac 100 Feet 10 9Vac 13 5Vac 150 Feet 11 43Vac 14 1Vac Next Step Products provides these guidelines as a reference for proper operation Failure to adhere specifications could result in improper operation or synchronization of lights ALL VO...

Page 8: ...K IMPROPERLY Measure and verify that proper low voltage is being supplied to lights see WIRE GAUGE WIRE LENGTH GUIDE CHART MOST IMPORTANTLY SEE CHART FOR MIN MAX VOLTAGE CORD LENGTH CHART 2013 14 SAVI LED LIGHTING PRODUCTS COLORED LIGHTS OUT OF SYNCH Follow Synchronization Instructions in this Guide Be very patient and read instruction carefully If lights fail to synchronize verify that proper wir...

Page 9: ... indicates the seal is not water tight Retighten the screws and test for bubbles again STEP 5 Reset the fixture into the wall fitting and turn the power ON Apply a new silicone bead to the lens with tube provided after cleaning the lens and body of old silicone WINTERIZING The water level should be lowered to approximately 12 inches below the pool lights make certain the water is drained out of th...

Page 10: ...In the event of a defect in material or workmanship during the warranty period the Company will repair or replace at its own discretion its products under the conditions of the warranty A complete list of the Company s brands and their warranty service contact information can be found at the end the warranty RETURN OF DEFECTIVE PRODUCT After contacting the proper company or division and receiving ...