8
Vuelift Planning Guide
Part No. 001123, 16-m05-2018
Safety First (Round)
3 & 5 rule (code prior to 2016)
The ASME A17.1/CSA-B44–Safety Code for Elevators and Escalators
(PRIOR TO 2016)
mandates
the following maximum hoistway door clearances (see drawing on next page).
• Clearance between the hoistway door and the hoistway edge of the landing sill shall not exceed
3” (76 mm).
• Distance between the hoistway face of the landing door and the car door shall not exceed 5”
(127 mm).
• Vuelift Residential Elevator design is with a maximum 1.25” (32 mm) running clearance.
3/4 & 4 rule (code 2016 and after)
The ASME A17.1-2016/CSA B44-16 Safety Code for Elevators and Escalators
(2016 AND AFTER)
mandates the following maximum hoistway door clearances (see drawing on next page):
• Clearance between the hoistway door and the hoistway edge of the landing sill shall not exceed
0.75” (19 mm).
• Distance between the hoistway face of the landing door and the car door shall not exceed 4”
(102 mm).
• Vuelift Residential Elevator design is with a maximum 1.25” (32 mm) running clearance.
Summary of Contents for Vuelift
Page 5: ...5 Part No 001123 16 m05 2018 Vuelift Planning Guide Chapter 1 Round Elevator Acrylic ...
Page 14: ...14 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 1 Plan view round ...
Page 16: ...16 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 3 Balcony detail round ...
Page 17: ...17 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 4 Thru floor detail round ...
Page 18: ...18 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 5 Elevation view round ...
Page 19: ...19 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 6 Provisions by others round ...
Page 20: ...20 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 7 Pit cutout detail round ...
Page 33: ...33 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 10 Plan view octagonal type 1 ...