Part No. 000682 15-m10-2015
Page 25 of 27
Orion Planning Guide
ORION STANDARD NOTES
HOISTWAY
o
The hoistway must be designed and built in accordance with the “Safety Code for Elevators and Escalators”
(ASME A17.1) and all state and local codes.
o
Due to close running clearances, the owner/agent must ensure that the hoistway and pit (where provided) are
level, plumb and square and are in accordance with the dimensions on these drawings.
MINIMUM OVERHEAD CLEARANCE
o
Owner/agent must ensure the minimum overhead clearance is in compliance with codes.
CONSTRUCTION SITE
o
Owner/agent to provide all masonry, carpentry and drywall work as required and shall patch and make good
(including
fi
nish painting) all areas where walls/
fl
oors may need to be cut, drilled or altered in any way to
permit the proper installation of the lift.
DIMENSIONS
o
Contractor/customer to verify all dimensions and report any discrepancies to our of
fi
ce immediately.
STRUCTURAL
o
Structural engineer to assure that the building and shaft will safely support all loads imposed by the lift
equipment. Refer to the tables on the installation drawings for loads imposed by the equipment.
o
Suitable lintels must be provided by the owner/agent. Door frames are not designed to support overhead wall
loads.
ELECTRICAL
o
Power supply with a lockable fused disconnect and auxiliary contact to brake the battery feed, or circuit
breakers with a 3-pole breaker for battery feed required in compliance with electrical code (contact your
Savaria dealer or refer to the table below for OEM part numbers).
o
Permanent power of 240V single-phase 40 Amp or 208V three-phase 30 Amp must be supplied by others
before installation.
o
Remote hall call (when supplied) to be installed by the owner/agent at 42” from the landing
fl
oor.
ENTRANCES
o
Entrance assemblies must be adjusted to align with the platform and interlock equipment. Others to allow an
adequate rough opening.
o
Entrance assembly must be securely fastened to walls by the elevator contractor.
Disconnect Switch Types & Accessories
Cutler Hammer
Federal Pioneer
Siemens
1 PHASE 5 H.P. Pump Unit
2 Pole Solid Neutral 240V 1 PH
1HD222N
1622SN
ID322
Required Auxiliary Contact
DS16CP
E1K-1AEV-W94
MSSAK 116
Required Type “D” Fuse (Buss type “FRN” or equal)
2@40 amp
2@40 amp
2@40 amp
3 PHASE 5 H.P. Pump Unit
3 Pole Solid Neutral 208V 3 PH
1HD321N
1332SN
ID321
Required Auxiliary Contact
DS16CP
E1K-1AEV-W94
MSSAK 116
Required Type “D” Fuse (Buss type “FRN” or equal)
3@30 amp
3@30 amp
3@30 amp
Cab Lighting
1 Pole Solid Neutral 120V 1 PH
GP 111N
86211
CFN 211
Required Type “D” Fuse (Buss type “T” or equal)
1@15 amp
1@15 amp
1@15 amp