2. SPECIFICATIONS

K2 Plus Specifications

Applications

Residential, indoor, straight-run stairway

Commercial (where permitted)

Load capacity

Residential: 400 lb (182 kg)

Commercial: 350 lb (159 kg)

NOTE

: Flip-up rail maximum load capacity is 350 lbs 

(159 kg)

Maximum travel

32 ft (9.75 m)

Travel speed

15 ft/min (0.08 m/s)

Daily cycle

Normal: 10

Heavy: 25

Excessive: 40

Maximum starts in 1 hour on standard installation: 5

Range of incline

30° to 55°

Temperature range

14°F to 104°F (-10°C to 40°C)

Drive system

Rack and pinion

Operator controls

Constant-pressure type (rocker switch and remote 
control call/send units)

Seat belt

Retractable

Motor

24 VDC, 1/3 HP, 2500 RPM

Noise level

Does not exceed 70 dBA

Fold-up width

16 5/8” to 18 1/4” (42.2 cm to 46.4 cm)

Fold-out width

27 3/8” to 29” (69.5 cm to 73.7 cm)

Rail

Aluminum extrusion

Charging

Charges on standard household power (110 VAC)

Emergency operation

Full up and down travel on power interruption (full 
battery backup)

Options

Savaria Link remote monitoring

Warranty

36 months

Summary of Contents for K2 Plus

Page 1: ...OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No 001188 08 m05 2020 K2 Plus Stairlift ...

Page 2: ...tions and a maintenance schedule for your Lift Upon completion of installation the Savaria mechanic must provide you with the information for the box below and ensure it is recorded in this owner s manual In addition either you or the Savaria mechanic must keep any service and or maintenance records in the Maintenance Record section of this owner s manual At all times your Lift must be maintained ...

Page 3: ...ures 7 Safety Features 7 Seat Belt 7 Footrest and Carriage Sensors 7 Safety Switches 7 Emergency Stop Button Optional 7 Overspeed Brake 7 Key Switch and Power Switch 8 4 OPERATION 9 Before Operating the Stairlift 9 Operating the Stairlift 9 Emergency Stop Optional 10 Emergency Manual Operation 10 5 TROUBLESHOOTING AND MAINTENANCE 12 Operator Troubleshooting 12 Stairlift Will Not Run 12 Stairlift i...

Page 4: ...fied personnelperform maintenance and service on the unit When replacing parts be sure that only genuine Savaria parts are used This lift is intended for use by a mature person who understands its proper operation as set out in this manual This lift is to be used ONLY for the transport of a person up down the stairway Do NOT use the lift for any other purpose such as the transport of items Do NOT ...

Page 5: ...xterior components of the K2 Plus Stairlift Figure 1 Backrest Folding Folding seat UP DOWN toggle switch Retractable seat belt Folding Carriage footrest Seat swivel handle Key switch Diagnostic LEDs armrests under arm ON OFF switch on top of carriage NOTE Plus seat shown here L seat also available ...

Page 6: ... 1 hour on standard installation 5 Range of incline 30 to 55 Temperature range 14 F to 104 F 10 C to 40 C Drive system Rack and pinion Operator controls Constant pressure type rocker switch and remote control call send units Seat belt Retractable Motor 24 VDC 1 3 HP 2500 RPM Noise level Does not exceed 70 dBA Fold up width 16 5 8 to 18 1 4 42 2 cm to 46 4 cm Fold out width 27 3 8 to 29 69 5 cm to ...

Page 7: ...e footrest These sensors will stop the stairlift if an obstruction is encountered on the stairway If you encounter an obstruction press the opposite side of the toggle switch to run the stairlift in the opposite direction Remove the obstacle from the pathway and proceed in the original direction of travel Safety Switches There are upper and lower safety limit switches to stop the stairlift when it...

Page 8: ...is inserted and turned a quarter turn clockwise to the ON position Once the key switch is turned on flip the ON OFF main power switch on the top of the carriage to the ON position Do NOT turn off the power switch after each trip Turning off the power switch stops the batteries from charging and this action will eventually drain the batteries Figure 2 NOTE Key switch Power switch NOTE Plus seat sho...

Page 9: ...o the required end of the rail for boarding Be sure to point the remote at the lift when pressing the button 2 If necessary fold down the seat armrests and footrest 3 Lift up the seat swivel handle rotate the seat to a comfortable boarding position and then release the swivel handle to lock the seat in place 4 Ensure the seat is locked in place before boarding 5 Position yourself in the seat and f...

Page 10: ... the seat armrests and footrest 14 For more information or training contact the installing company Emergency Stop Optional In the event of an emergency you can press the optional red Emergency Stop button located on the arm of the chair The stairlift will stop immediately Once the emergency is dealt with release the button to restore normal operation Emergency Manual Operation If necessary you can...

Page 11: ...ft hand unit turn the handle clockwise for the unit to travel up the stairs and counter clockwise for the unit to travel down the stairs 5 For a right hand unit turn the handle clockwise for the unit to travel down the stairs and counter clockwise for the unit to travel up the stairs 6 Whenmovement ofthecarriage iscomplete callyourAuthorizedDealerfor service assistance DO NOT turn the main power b...

Page 12: ... sure the seat is swiveled and locked in the riding position 2 Check around the footrest and carriage for any obstructions If the stairlift does not operate after checking the above items contact your authorized Savaria dealer Stairlift is beeping while not moving If the stairlift beeps for approximately 20 seconds while not moving this means the stairlift is not charging Check that the stairlift ...

Page 13: ...eft Middle LED on Obstruction both right hand and left hand All LEDS off Safety circuit fault All LEDs on Ready to run left or right Maintenance The owner can perform the 3 month checks however the 6 month checks and other maintenance must be performed by a qualified technician Contact your Savaria dealer Units installed in adverse environments will require additional maintenance on a monthly basi...

Page 14: ...witches Ensure the unit stops at the required position at the top and bottom of the stairway Check the operation of the overspeed brake Lubricate the angle and straight rollers with synthetic grease super lube or wet graphite grease Check that the top mechanical limits are tight Check that the rail brackets are tight Check that the gear rack is tight and pitched properly Check that the footrest is...

Page 15: ...15 Part No 001188 08 m05 2020 K2 Plus Stairlift Owner s Manual Maintenance Record Date Time Reason for Call Comments Dealer ...

Page 16: ...Walker Drive Brampton Ontario L6T 5E1 Canada www savaria com For service or questions about this product please contact your installing dealer DEALER NAME _________________________________________________ DEALER PHONE _________________________________________________ Authorized Savaria Dealer ...

Reviews: