Operator Troubleshooting
The following table lists potential problems and their possible solutions.
If the problem persists, contact your Authorized Dealer.
Potential Problem
Possible Solution
Platform travels up but not
down
Check the underpan sensor. Pull down on the
underpan to ensure the pan is not stuck in the
activated position.
Check the flap on the lower part of the lift. Move
it to ensure the switch (if equipped) is not stuck
in the activated position.
Platform travels down but not
up
Check the flap on the upper part of the lift. Move
it to ensure the switch (if equipped) is not stuck
in the activated position.
Platform does not move in
either direction
Check the power supply (breaker, cord, etc.).
Check that the key is ON (if applicable).
Check to see if the Emergency Stop is pushed in;
it should be pulled out for normal operation.
If the platform is at the top landing, check the
underpan sensor and the flap on the lower part
of the lift as described above.
If the platform is at the bottom landing, check
the flap on the upper part of the lift as explained
above.
Check that the arms are not in an intermediate
position. They should be in a horizontal or
vertical position.
Platform does not fold or unfold
(power-fold option only)
Check that the lift is stopped at one of the
landings.
Check that the seat is folded up.
Platform moves intermittently
Check to see if the bus lines (if equipped) are
dirty. If necessary, clean with grit #400
sandpaper.