5. POWER FAILURE AND EMERGENCY LOWERING
In the event of a power failure, the elevator is equipped with a Battery Back-Up
system that allows you to lower the elevator from the inside of the cab. This
device operates on batteries and is only activated if a main power supply failure
occurs. The operation is as follows:
1
Press any Landing button below the floor where the elevator is located.
2
On arrival at the selected floor, the landing door will automatically unlock.
3
If there is an automatic gate, the gate will open.
4
Remove the key, open the manual gate (if equipped) and exit the cab.
6. EMERGENCY LIGHTING
In the event of a main power failure, the emergency COP light will turn on
automatically.
If one of the cab ceiling lights burns out, replace the bulb with a
10W bulb ONLY.
7. MANUAL LOWERING
In the event of a power failure, the UPS lowers the cab to the next landing and
opens the doors. Should the UPS fail, you can use the telephone to call for help.
The Manual Hand Crank can then be used to lower the elevator.
1
Instruct the passenger (s) in the elevator to remain calm and stay well back
from the door of the elevator. Ease their concern by telling them your
intentions.
2
Switch the main disconnect switch for the main power supply to the
elevator controller to the “OFF” position.
3
Locate the Motor Access Door, insert the Manual Hand Crank onto the
motor shaft and crank the elevator to the next lowest level.
4
To exit the cab, open the landing door (using the special emergency key)
and assist the passenger(s).