Eclipse (Micro-6) Owner’s Manual

Part No. 000841, 12-m01-2018

4. OPERATION

Operating from the Landing Controls

1

If equipped with a key switch, insert the key into the key switch on the Hall 
Call station and turn the key to the ON position.

2

Press the Hall Call button once and release. The elevator will automatically 
come to your landing.

3

Turn the key (if equipped) to the OFF position and remove the key.

4

If required, turn the door handle and pull the door open.

Note that if you open the door and don’t open the gate (or interrupt 
the light screen, if equipped), the unit will not take the next call and 
will beep three times.

5

If the cab has a manual gate, slide the gate open and enter the cab.

6

Once inside the cab, close the gate, insert the key (if equipped) into the key 
switch on the Cab Operating Panel, and turn the key to the ON position.

When using the landing controls, the cab can only be moved 
(called) to the level from which you are calling. When using the 
control buttons in the cab, the cab can be moved to any level.

Wheelchair wheels must be locked at all times when the 
elevator is moving.

NOTE

WARNING

Summary of Contents for Eclipse

Page 1: ...OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No 000841 12 m01 2018 Eclipse Residential Elevator with Micro 6 Controller ...

Page 2: ...r more frequently where usage environment or local jurisdiction requires As the Owner you are responsible for ensuring that regular service and inspections occur in a timely manner Refer to this manual for specifications operating instructions and maintenance of the Eclipse Residential Elevator Upon completion of installation the dealer must provide you with the following information and ensure it...

Page 3: ...1 SPECIFICATIONS 5 2 FEATURES 6 3 OPTIONS 8 4 OPERATION 9 Operating from the Landing Controls 9 Operating from the Cab Operating Panel COP Controls 10 Cab Lights 10 5 POWER FAILURE AND EMERGENCY LOWERING 11 6 EMERGENCY LIGHTING 11 7 MANUAL LOWERING 12 8 DIAGNOSTICS 13 9 MAINTENANCE 14 Maintenance Record 15 ...

Page 4: ...ll equipment labels at all times Replace any damaged labels immediately Ensurethat only qualified personnelperform maintenance and service on the unit When replacing parts be sure that only genuine Savaria parts are used This unit is intended for use by a mature person who understands its proper operation as set out in this manual Prior to operation make sure that All doors and gates are locked an...

Page 5: ... x 48 x 80 914 mm x 1219 mm x 2032 mm 36 x 54 x 80 914 mm x 1372 mm x 2032 mm 36 x 60 x 80 914 mm x 1524 mm x 2032 mm 40 x 54 x 80 1016 mm x 1372 mm x 2032 mm Control system Micro 6 controller with diagnostics Pit depth required 6 152 mm 11 279 mm minimum with buffer springs Minimum overhead clearance 96 2438 mm for standard 80 cab 114 2896 mm for 96 cab Cab panel finish Solid melamine or MDF pane...

Page 6: ...k Emergency lights Final limit switch Mechanical rail shoring blocks Preset slack chain safety brake and switch Options 84 high cab 96 high cab Rated speed of 50 ft min 0 25 m s available where code permits Accordion car gate choice of style Automatic gate operator accordion gates only Buffer springs 11 pit depth minimum Laminate flooring in finished oak maple or cherry Interlocks for doors by oth...

Page 7: ...anding button is pressed the cab will automatically move to the landing The cab will stop when the selected landing is reached 3 Alarm Button Figure 1 C This button can be pressedat anytime tosound the alarm in case of an emergency 4 Run Stop Button Figure 1 D This button can be used at any time to stop the cab and activate the alarm buzzer 5 Keypad Phone Figure 1 E For units that have a keypad ph...

Page 8: ... optional key switch limits the use of the elevator to authorized persons only 9 Landing Door and or Gate Interlock The Landing Door Gate lock prevents the movement of the cab unless the door gate is in the closed and locked position If the door gate is not completely closed the cab will not move 10 Emergency Battery Operation In the event of a building power failure the system is provided with a ...

Page 9: ...The door timer is inoperative when this feature is activated Automatic Gate Opener 1 Press the Landing Hall Call button to call the elevator If the entrance door is equipped with an automatic door opener it will open automatically once the elevator stops at the landing otherwise open the entrance door manually 2 The gate will open automatically once the entrance door is fully open If the cab is eq...

Page 10: ...oor open Note that if you open the door and don t open the gate or interrupt the light screen if equipped the unit will not take the next call and will beep three times 5 If the cab has a manual gate slide the gate open and enter the cab 6 Once inside the cab close the gate insert the key if equipped into the key switch on the Cab Operating Panel and turn the key to the ON position When using the ...

Page 11: ...sition and remove the key 4 Unlock the wheelchair wheels if applicable and exit the cab If the cab is equipped with a gate the gate must be closed after exiting the cab If the gate is left open all controls will remain inoperable Theoutsidelandingdoormustbeclosedafterexitingorentering the cab If the outside landing door is left open all controls will remain inoperable Cab Lights If the cab door is...

Page 12: ...in power failure the emergency COP light will turn on automatically If one of the cab ceiling lights burns out replace the bulb with a 10W bulb ONLY 7 MANUAL LOWERING In the event of a power failure the UPS lowers the cab to the next landing and opens the doors Should the UPS fail you can use the telephone to call for help The Manual Hand Crank can then be used to lower the elevator 1 Instruct the...

Page 13: ...s a problem in one of the following areas overload trip run timer trip main safety chain open door lock fault or auto shutdown counter 1 long beep 2 seconds followed by 2 short beeps 1 2 second Contact your authorized Savaria dealer for service There is a problem with re level shutdown or the low pressure switch is activated 1 long beep 2 seconds followed by 3 short beeps 1 2 second Contact your a...

Page 14: ... hinges and adjust the door closure if required 3 Lubricate the rails with light grease such as white lithium 4 For a Gatemate operator lubricate the shaft and bushing using a general silicone lubrication spray lubricate on installation as well 5 Inspect the travelling cable for wear Replacethecable ifanycutsordamage to the jacket are evident 6 Replace the batteries inside the control panel as ind...

Page 15: ...15 Part No 000841 12 m01 2018 Eclipse Micro 6 Owner s Manual Maintenance Record Date Time Reason for Call Comments Dealer ...

Page 16: ... Inc 2 Walker Drive Brampton Ontario L6T 5E1 Canada www savaria com For service or questions about this product please contact your installing dealer DEALER NAME _________________________________________________ DEALER PHONE _________________________________________________ Authorized Savaria Dealer ...