USAI RECESS PINHOLE
SERVICE INSTRUCTIONS
CAUTION READ BEFORE INSTALLATION
• Retain these instructions for future reference. This product must be installed by a person familiar with the
construction and operation of the product and the hazards involved, in accordance with applicable NEC code.
• Switch off main power before beginning installation.
• Install per national installation and accident prevention regulations.
• Clearance between sides of luminaire and parts of building to be 1/2 inch minimum; clearance to insulating
materials to be 3 inch minimum, unless luminaire is IC rated.
• Fixtures must be installed in applications where the ambient temperature does not exceed 40o C during
normal operation.
• DO NOT connect or disconnect LED board wire connector when the fi xture is energized. This may result in
permanent damage to the LED array.
• Warranty claims will not be accepted if incorrect driver or light engine is used.
Page 3
OPTIC REPLACEMENT FOR ADJUSTABLE:
Caution: Power Must Be Off
1. Remove trim from housing.
2. Loosen thumb screws (2X).
3. Remove optic by pulling.
4. Install optic by aligning pins to optic holder receptacle
and pushing into place.
5. Install heatsink assembly and secure with thumb screws (2X).
6. Make sure optic is flush with glass.
7. Install trim into housing.
Thumb
Screw
Optic
LIGHT ENGINE REPLACEMENT FOR ADJUSTABLE:
Caution: Power Must Be Off
1. Loosen thumb screw (2X)
2. Lift and rotate heatsink assembly.
3. Remove optic.
4. Disconnect Light Engine.
5. Remove Light Engine mounting screws (3x).
6. Remove Light Engine Holder.
7. Replace Light Engine.
8. Install remaining parts in reverse order.
Heatsink
Assembly
Thumb
Screw
Light Engine
Holder
Light
Engine
Optic
Light Engine
Mounting
Screws (3X)
© 2018. USAI, LLC.
All rights reserved.
All designs protected by copyright.
Covered by US Patents. Patents pending.