4. For daisy-chaining modules, connect the RJ-45 Data Out connector on the left side in the transorb
board of the first module with another Cat 5/5e/6 cable terminated on both ends with RJ-45
connectors to the next transorb board Data In port.
5. Connect the Station port (as shown in the previous figures) on the SSL-P018 or SSL-P002 to the
SKL-1000 (RS232) or the SKL-4000 (RS-422 In).
Connecting a Savant SmartLighting Controller to an SKL-1000
If an SKL-1000 is used in the SmartLighting system, you must configure the SSL-P002 or SSL-P018 to
communicate using the same serial port standard. By default, the SKL-1000 uses RS-232. The SSL-P002
or SSL-P018 use RS-422.
To set up the SSL-P002 or SSL-P018 to connect to an SKL-1000 do either of the following procedures.
Using Windows
1. Open LiteWare and go to the
Control Panel
.
2. Click the
IP
Address Book
button.
3. Click the
SEARCH
button.
4. From the
Equipment Locator
tab, select a service for an
SSL-P018
or
SSL-P002
.
5. Click
Configure
beside the selected service. The
Serial Port Configuration
screen appears.
140915 009-0885-01 Savant SmartLighting Control Conversion Application
11 of 22