The Savant® SmartLighting 2 with PoE (SSL-P002) Quick Reference
Guide provides all the steps necessary to operate the SSL-P002.
The SSL-P002 supports up to 40 keypads through the SKL-4000
and 12 keypads through the SKL-1000. The SSL-P002 supports
Power over Ethernet (PoE) using the PoE IEEE 802.3af standard.
Box Contents
(1) SmartLighting 2 Controller with PoE (SSL-P002-00)
(1) Installation Kit (075-0134-xx)
(8) Flat Phillips Screws - #6 x 1/4 (039-0143-xx)
(2) Side Mount Brackets - pair (071-0625-xx)
Quick Reference Guide (this document)
Specifications
Environmental
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 80% Relative Humidity (non-
condensing)
Cooling
2 cubic feet per minute (CFM)
recommended.
Maximum BTU
10 BTU/hr
Dimensions and Weight
Dimensions and Weight
Height
1.59 in (4.04 cm)
Width
4.32 in (10.96 cm)
Depth
6.50 in (16.51 cm)
Weight
3 lb (1.36 kg)
Rack Space
1U
Power
Power
Power over Ethernet
(PoE)
IEEE 802.3af
Power Supply
(Optional)
5V DC
1.25A
120-240V AC 50/60 Hz
Maximum Power
5 watts
Regulatory
Regulatory
Safety and Emissions
FCC Part 15 | CE Mark | C-Tick
RoHS
Compliant
Minimum Supported Release
Minimum Supported Release
Savant OS
da Vinci 5.0.2
Front Panel
Ground Connector - used to connect to a
suitable ground reference when using Power
over Ethernet.
CPU Status
LED
Green:
SSL-P002 is operating normally.
Green Flashing:
Controller is starting.
O
ff
:
Unit is rebooting
Red:
Firmware update has failed and unit will
be rebooted.
Red Flashing:
No IP Address/Connecting to
Network.
Amber:
Firmware update in process.
Amber Flashing:
Controller has a link-local IP
Address. This applies to controllers that are
not connected to an active router and may be
connected directly to a computer.
5VDC
Reset
Station
Ethernet
Module
A
B
C
D
E F
G
H
Reset Button
Press and hold for 5 seconds while powered
On to clear network settings.
Status
LED will
blink rapidly when reset is complete.
PoE/Ethernet
10/100 Base-T auto-negotiating port with
Link/Activity LEDs: 8-pin RJ-45 female.
Link LED
O
ff
:
Ethernet link is not established.
Green Solid:
Ethernet link is established.
Green Blinking:
Ethernet activity is
occurring.
Date Rate
LED
O
ff
:
10 Mbps data rate
Green:
100 Mbps data rate
Station
Used to communicate with SKL-1000 and
SKL-4000 via RS-422. See
.
Module
Used to communicate with SmartLighting
module via RS-422.
Power Input
5V DC 1.25A - Connect to optional power
supply when not using PoE.
Cable Tie
Mount
Holds the power cable with the cable tie.
Note
: The SSL-P002 Station port defaults to RS-422 but is configurable to
RS-232 by a Savant dealer. For more details, see
Changing the Serial Port.