Box Contents
(1) SmartControl 2 (SSC-W002G-00)
(1) Installation Kit SmartControl 2 (075-0174-xx)
(1) Mounting Plate (074-0569-xx)
(1) 6-pin Screw Down Plug-in Connector (028-9352-xx)
(1) 5V DC 1.2A Power Supply (025-0165-xx)
(1) Cable Tie (014-0071-xx)
(1) Quick Reference Guide (this document)
Specifications
Environmental
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 80% RH (non-condensing)
Dimensions and Weight
Dimensions and Weight
Height
0.64 in (1.62 cm)
Width
2.70 in (6.85 cm)
Depth
2.67 in (6.78 cm)
Weight
Net: 0.25 lb (0.11 kg)
Weight
Shipping: 1.50 lb (0.68 kg)
Power
Power
Input Power
5V DC 1.2A
Max Power
6 watts
Standards
Standards
Wireless
Wi-Fi (802.11 b/g/n 2.4 GHz)
Security
WPA1™, WPA2™, WPA1™ + WPA2™, WEP
Regulatory
Regulatory
Safety and Emissions
FCC Part 15 | CE Mark | C-Tick
Contains FCC ID:
TLZ-CU277
Contains IC:
6100-CU277
RoHS
Compliant
Minimum Supported Release
Minimum Supported Release
Savant OS
da Vinci 7.0
Network Requirements
Savant requires the use of a wireless network that is configured to
make use of at least one of the supported wireless Standards listed in
the Specifications Table.
Connect all Savant devices to the same local area network (LAN) or
subnet as the host. Savant recommends not implementing any type of
tra
ffi
c or packet shaping in your network topology for the Savant
devices as this may interfere with performance.
Network Configuration
To ensure that the IP Address will not change due to a power outage, a
static IP Address or DHCP reservation should be configured. Savant
recommends using DHCP reservation within the router. By using this
method, static IP Addresses for all devices can be managed from a
single UI avoiding the need to access devices individually.
Setting DHCP reservation varies from router to router. Refer to the
documentation for the router to configure DHCP reservation.
Connecting to a Wireless Network
Refer to the SmartControl 2 (SSC-W002G) Deployment Guide located
on the
Savant Customer Community
to connect the SSC-W002G to
the network.
Front Panel
A
Press and hold for 5 seconds while powered On to clear network
settings.
Status
LED will blink rapidly when reset is complete.
O
ff
:
No Power
On Solid:
Connected/Communicating with the Savant host.
Blinks Once:
In Access Point Provisioning Mode and is ready to
be provisioned onto the local network.
Blinks Twice:
Is connecting to the local network.
B
Blinks Three Times:
Is connecting to the host.
Short O
ff
Blink:
Firmware is updating.
Rapid Blink:
The reset button was held down for at least five
seconds and the SSC-W002G is performing a factory reset.
Rear Panel
GPIO (General Purpose Input and Output Ports)
6-pin Screw Down Plug-in Connector (Left 3 Pins).
See
for pinouts.
GPIO (General Purpose Input and Output Ports)
6-pin Screw Down Plug-in Connector (Left 3 Pins).
See
for pinouts.
GPIO Input
When configured as an input, the processor will
look for a low (<0.8V DC) or high (>2.4V DC )
state.
Minimum 0V DC / Maximum 12V DC
GPIO Output
When configured as an output, the port provides
a binary output of 0-12V DC 150mA max.
Normally Open / Normally Closed - Relays
6-pin Screw Down Plug-in Connector (Right 3 Pins)
Normally Open / Normally Closed - Relays
6-pin Screw Down Plug-in Connector (Right 3 Pins)
Relay
Dry contacts (normally open/normally closed) to
control devices requiring basic on/o
ff
operation.
Max: 30V DC 1A.
Input Power
5V DC 1.2A Connect to included power supply.
Cable Lance
Use with included cable tie to secure power
supply connection.
SSC-W002G-00 | 009-1257-01 | 160210